Configure the device using the Digi ConnectPort X Family web interface
Administration
Digi ConnectPort X Family
214
Field
Description
XBee network
errors
This section includes error counts for all activity on the XBee network. Use these
values to determine the quality of sent or received data.
Removed from queue
: The number of frames not transmitted due to a time
limit set by an application.
Unable to transmit
: The number of frames not transmitted due to a
transmission error. This includes duty cycle limits and CCA and PHY errors.
Address not found
: The number of transmitted frames for which the network
address of a remote node could not be found.
Route not found
: The number of transmitted frames for which the route to a
remote node could not be found.
Not acknowledged
: The number of transmitted frames not acknowledged by
the remote node.
No response or status
: The number of transmitted frames for which no
indication of success or failure was received from the local radio.
XBee device status page
Configuration > Network > XBee > Device Status
displays detailed information on the state of Digi
device and its role as a gateway device in the XBee network. The parameters displayed vary based on
the capabilities supported by the node's XBee module. See
.
SureLink statistics
Digi SureLink provides an “always-on” mobile network connection to ensure that a Digi device is in a
state where it can connect to the network. The statistics displayed for Digi SureLink pertain to the
periodic tests, known as Link Integrity Monitoring tests, that run over the established PPP connection
to ensure that end-to-end communication is possible. There are three Link Integrity Monitoring tests
available: Ping Test, TCP Connection Test, and DNS Lookup Test. For descriptions of these tests, see
Link integrity monitoring settings
. In these SureLink statistics, a “session” is a PPP session. The
session statistics are reset to zero at the start of a new PPP connection. The “total” statistics are the
accumulated totals for all sessions since the device booted. The “tests” are the SureLink Link Integrity
Monitoring tests that you configured to be run when establishing the mobile network connection.
n
Session Successes
: The number of times a configured test ran and succeeded in the current
PPP session.
n
Session Failures
: The number of times a configured test ran and failed in the current PPP
session.
n
Session Consecutive Failures
: The number of consecutive failures for a test, with no success.
When a test is successful, the consecutive failures counter resets to zero. The consecutive
failures counter indicates a device's “progress” toward the configured maximum number of
consecutive failures, after which the PPP link goes down (and restarts).
n
Session Bypasses
: SureLink testing bypasses a test when a configuration parameter is bad.
This means the test was not run. If the PPP connection goes down while a test is in progress,
the SureLink testing classifies the test as bypassed, since it could not be run. (Note that the
PPP link may go down for many reasons, independent of SureLink testing.)
n
Total Successes
: The total number of times a configured test ran and succeeded since you
started the Digi device.