Configure the device using the Digi ConnectPort X Family web interface
Configuration through the web interface
Digi ConnectPort X Family
170
n
Device Descriptors
:
l
Device ID
: A numeric identifier for the Digi device, used internally by the Ekahau Positioning
Engine for device tracking over time. Each Digi device located on the network requires a
unique identifier.
l
Device Name
: A descriptive name to identify the Digi device to users. The maximum length
of this device name is 50 characters.
Industrial Automation-Modbus-Bridge
Industrial Automation is supported in the following Digi devices:
n
ConnectPort X2 (non-Python version) and ConnectPort X4
Currently, from the web interface, it is only possible to select a different port profile than
Industrial Automation
, or change the serial port settings, such as baud rate and parity. If changes
are needed from the settings established by the Industrial Automation port profile, use the
set ia
command from the command-line interface.
For more information on Industrial Automation, see the
set ia
command description in the
Digi
Connect® Family Command Reference
and the application note
Remote Cellular TCP/IP Access to Modbus
Ethernet and Serial Devices
available on the
Known limitations
n
You can use Digi RealPort only when the Modbus Bridge function is disabled. You cannot use
RealPort with Modbus/RTU or ASCII to access the Modbus Bridge function.
n
The outgoing slave idle time used for remote Modbus IP-based slaves does not always close
idle sockets predictably.
n
While the Modbus bridge is active, do not attempt to “Port Forward” TCP 502 or UDP 502 to
local Modbus/TCP servers while the Modbus Bridge is active. This causes neither function to
work. Disable the Modbus Bridge if you want traditional Router/NAT function for Modbus/TCP
port 502.
Enable or disable Modbus Bridge
To enable or disable Modbus Bridge, choose one of the following options:
n
To disable the Modbus Bridge, select a different port profile than Industrial Automation.
n
To enable Modbus Bridge, reselect the Industrial Automation port profile.
Note
Any specialized settings configured using the
set ia
commands are lost when you disable
the Modbus bridge. You must reconfigure these settings when you re-enable the Industrial
Automation port profile.
PPP (Point-to-Point Protocol)
PPP (Point-to-Point Protocol) provides TCP/IP communication over a modem connected to a serial
port on your Digi ConnectPort X server. PPP allows you to connect a device to a network using a
telephone line and the device has access to the resources of the network as if it were directly
connected to the network. Use the PPP (Point-to-Point Protocol) page to connect incoming clients or
serial devices to an external network using modems and telephony to maintain the connection.