Setting the number of time slots to 1 disables anti-collision capability (i.e. tags
must be read one at a time)
“Signal level threshold” permits to report a tag only if its signal level is greater or equal to this
threshold during asynchronous read. All tags will be reported if the threshold is set to 0.
“Quiet tags once read” requests tag to stay quiet once read.
Advanced
“Set write option flag” specifies if write option flag should be set for all subsequent ISO
15693 write and lock commands. This behavior depends on tag manufacturer. See tag
specifications for more information.
“Set protocol extension flag” specifies if protocol extension flag should be set for all
subsequent ISO 15693 commands.
9.4.2
Information and State Tab
Figure 53: ISO 15693 panel (Information and State tab)