MCQ-PRO RFID Reader
— Installation and Tuning Manual Version 1.00
Page 51 of 89
With a MCQ-Pro Reader, if this mode is active, the reader uses GPIO Output
#2 to report reading activity. GPIO Output #2 is activated when the reader
“sees” tags in the RF field. The time an output remains active after the
corresponding event has occurred is software configurable.
“Enable Tunnel Feedback” is for DIALOC ID internal use only.
“Enable Scan Once” indicates, when reading asynchronously, that the radio should
automatically stop reading after:
o
In “default RF” read mode: one single round (not valid with C210 & C220
tags).
o
In “multiplexer” read mode: having scan all the existing patterns.
You can configure read mode settings on “Read Mode” tab of “
Read Configuration” panel.
Figure 40: Read Configuration panel (Read Mode tab)
Input Trigger:
Active Level:
indicates the active level when radio should start reading (ie: on Low
state “0” or on High state “1”)
Output Feedback:
Duration:
indicates the duration in milliseconds of read activity feedback.
Tunnel Feedback:
Those settings are for DIALOC ID internal use only.
Содержание MCQ-PRO
Страница 1: ...User Manual Version 1 00...