User Manual for DEVO-12
Page 79 of 238
The interface will show the current status of flight mode, input value, output value
,
curve graph, and the adjustable items.
1) Flight
mode
The current status of flight mode is shown in gray characters.
2) Pitch
Click the navigation mark of Pitch and expand into two options of Normal and Original.
Select the desired item.
3) Exponential
setting
Click the navigation mark of Exponential and expand into two options of Off and On.
The curve will be smoothly changed if touching On. Select the desired item.
4) Curve
Setting
The setting is divided into two steps. Firstly choose the point that you want to adjust,
and secondly adjust its amount.
4.1) Point setting
Touch the navigation mark of Point and expand into nine points. Click the point which
you want to adjust.
4.2) Status setting
Touch the navigation mark of Status and expand into Inhibit and Active. Click Inhibit
for unchanging the said point’s amount. The default setting is Inhibit.
Click Active for changing the said point’s amount, and a dropdown menu of Output is
shown below.
4.3) Output setting
Touch the left or right navigation mark of Output to respectively decrease or increase
the said point’s amount. The adjustment range is from -100% to +100%.
The right curve graph will be changed synchronously when adjusting the said point’s
amount.
Click the icon
to exit after finished.
Note
: if an AVCS gyro is used, this function is not necessary.
3.11 Dual pitch
The dual pitch function is offered to the helicopter which needs two pitches. Pitch 2
should be selected at Device Output in Model Menu if want to use this function (Refer
Содержание DEVO-12