User Manual for DEVO-12
Page 221 of 238
1) Elevator stick setting
This function is that this point will become the cut-off point whether to mix if the
elevator stick position is set at one point. When the elevator stick is moved down from
this point, the mix will be cancelled; while the elevator stick is moved up from this point,
the mix will be activated.
Touch the left or right navigation mark of Elevator Stick to decrease or increase,
respectively, the value with a range of D1 – 100%. When the elevator stick is moved
down from this value, the mix will be cancelled; while the elevator stick is moved up
from this value, the mix will be activated. The default setting is Inhibit.
2) Rudder stick setting
The setting is same as above. The adjustable range is L/R 1 – L/R 100%.
3) Mix
value
setting
There are total five flight modes. The flight mode should be previously set at Device
Select in Mode Menu (refer to “2.10 Device Select”).
Touch the navigation mark of Left to change the leftward mix value of aileron to rudder.
It is possible to alter the mix direction via changing the sign before the value. The
adjustable mix is
± 125%.