User Manual for DEVO-12
Page 151 of 238
as well as Throttle Hold Switch is set as HOLD SW (Refer to “2.10 Device Select”).
Click the left or right navigation mark of the flight mode, which you want to
automatically adjust, to decrease or increase the amount of gyro gains, respectively. If
the gyro you use has two modes of NOR or AVCS, when the amount is less than
50.0%, NOR mode is activated. The lesser the amount is, the bigger the gyro gain
becomes. The default setting is 50.0%.
Click the icon
to exit after finished.
3.11 Governor
Governor should be set at Device Output (Refer to “2.11 Device Output”).
The control proportion of governor can be separately set in various flight modes. For
the absolute revolution amount, please set in external governor. The amount shown in
DEVO-12’s governor is just a percentage for reference. The actual revolution should
be read in the external governor.
Setting method:
Touch the icon
to enter Function Menu, and then click the icon
to
enter the interface of Governor.
The output channel, current statuses of flight modes and usable flight modes are
shown in the interface. According to the requirement, touch the corresponding flight
mode to set the amount. Click the left or right navigation mark to separately decrease
or increase the amount. The adjustable range is ± 125%.
The usable flight modes include Normal Mode, Stunt 1, Stunt 2, Stunt 3, Stunt 4, and
Throttle Hold.
Click the icon
to exit after finished.
Содержание DEVO-12
Страница 239: ...G G G G G G G G G G G...