1) Pos 0 setting
Touch the left or right navigation mark of Left at Pos 0 to change the leftward mix value
of aileron to flap.
Touch the left or right navigation mark of Right at Pos 0 to change the rightward mix
value of aileron to flap.
The mix direction will be revised by changing the symbol of plus or minus before the
value. The adjustable range is ±125%.
2) Pos 1 setting
The setting is same as the above.
3) Throttle
Stick
setting
The switch between Pos 0 and Pos 1 can be realized by setting the position of throttle
stick. Touch the left or right navigation mark of Throttle Stick to the position amount of
throttle stick. The default setting is Inhibit. The adjustable range is 0.0-100.0%.
4) Switch
setting
Touch the navigation mark of Switch and expand a dropdown menu including some
selectable items. Click the desired item and “0” before the item will be changed into
“1”. If two or more items are selected, And should be selected. Then touch the
navigation mark to return back.
Click the icon
to exit.
3.17 Pitch curve
Pitch Curve can be adjusted via nine points. Pitch curves of Pos 0 and Pos 1 can be
set, respectively. The item Pitch should be previously set in Device Output at Model
Menu (Refer to “2.12 Device Output”).
Setting method: