![Detroit Diesel DDEC VI Скачать руководство пользователя страница 461](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033461.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
APPENDIX C: PARAMETER LIST
Diagnostic
Name
Parameter
Group
Min
Max
Default
Access
Range
0 Speed
Gov TSC1
Condition
22
0
16
0
DRS, VEPS
0 - Series 60; 16 - MBE
1 Speed
Gov TSC1
Condition
22
0
16
0
DRS, VEPS
0 - Series 60; 16 - MBE
2 Speed
Gov TSC1
Condition
22
0
16
0
DRS, VEPS
0 - Series 60; 16 - MBE
3 Speed
Gov TSC1
Condition
22
0
16
0
DRS, VEPS
0 - Series 60; 16 - MBE
1 01 DI
Selection
13
0
3
0
DRS, VEPS
0=disable, 1=enable Dual Speed Axle,
2=enable transmission retarder input,
3=FUSO Auxiliary brake cut switch
1 021 DI
Selection
13
0
2
1
DRS, VEPS
0=disable, 1=enable park brake
interlock, 2=FUSO Park brake switch
1 05 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
1 10 DI
Selection
13
0
2
0
DRS, VEPS
0=disable, 1=enable aux shutdown,
2=FUSO Accelerator switch
1 15 DI
Selection
13
0
3
1
DRS, VEPS
0=disable, 1=Shutdown override
/ Diagnostic Request (Fault Code
Flashing), 2=CC-Cancel, 3=Diagnostic
Request (Fault Code Flashing)
2 08 DI
Selection
13
0
2
1
DRS, VEPS
0=disable, 1=Remote-Throttle enable,
2=Service-Brace active
2nd Axle
Speed Switch
Con
fi
g
13
0
3
0
DRS, VEPS
0=hardwired, 1=Ccvs1, 2=Ccvs2,
3=Ccvs3
3 01 AI
Selection
13
0
3
0
DRS, VEPS
0=no sensor, 1=air
fi
lter restriction
sensor, 2=OI Thermostat input,
3=FUSO Clutch pedal sensor input
3 05 AO
Selection
9
0
4
0
DRS, VEPS
0=disabled, 1=oil pressure lamp, 2=5
bar oil pressure gauge, 3=10 bar oil
pressure gauge, 4=fuel
fi
lter sensor
3 06 AO
Selection
9
0
3
0
DRS, VEPS
0=disabled, 1=coolant temperature
lamp, 2=coolant temperature gauge,
3=OI Thermostat input
3 07 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
All information subject to change without notice.
(Rev. 01/07)
C-1
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION