![Detroit Diesel DDEC VI Скачать руководство пользователя страница 215](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033215.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
5.1
ACCELERATION LIMITER
TBD
5.1.1
PROGRAMMING REQUIREMENTS AND FLEXIBILITY
The parameters and options for Acceleration Limiter are listed in Table 5-1.
Parameter
Group
Parameter
Description
Options
Default
Series
60
Setting
Access
23
Noise Max
Engine Speed
Maximum engine
speed for noise
trigger control
0 – 4000 rpm
1600 rpm
1800
rpm
VEPS,
DRS
23
Noise Min
Engine Speed
Minimum engine
speed for noise
trigger control
0 – 4000 rpm
1400 rpm
1350
rpm
VEPS,
DRS
23
AL Min Engine
Torque
Minimum engine
torque during
accelerations
0 – 100%
100%
15%
VEPS,
DRS
23
Enable Noise
Control
Enable noise control
function
0 – VCU Style
1 – DDEC Style
1 – DDEC
Style
1 –
DDEC
Style
VEPS,
DRS
23
AL Ramp Up
Rate
Sets acceleration rate
while in noise control
0 – 8191 rpm/s
160 rpm/s
120
rpm/s
VEPS,
DRS
Table 5-1
Acceleration Limiter Parameters and Options