DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.3.7
DPF REGENERATION LAMP (HARDWIRED AND J1939)
The purpose of this lamp is to let the operator know that a parked regeneration is required. This
lamp can be hardwired or multiplexed. Solid illumination indicates a manual regeneration is
required.
NOTE:
This function is optional.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The DPF Lamp is wired to pin 1/5 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-33.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
1 05
DO Fault
Detection
—
0 – Disabled
1 – Enabled
0 — Disabled
VEPS or
DRS
46
DPF Lamp
Con
fi
g
—
0 – Hardwired
1 – J1939 PTC1
0 – Hardwired
VEPS or
DRS
Table 4-33
DPF Regeneration Lamp Programming Options