![Detroit Diesel DDEC VI Скачать руководство пользователя страница 267](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033267.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Programming Requirements and Flexibility
The MCM options for the single-speed fan – Type 4 are listed in Table 5-33.
Parameter
Setting
Options
Default
Access
Fan Type
4 – Single-Speed
Fan – 2 Outputs
0 = 2–Speed Fan with Ambient Temp Offset
1 = 2–Speed Fan
2 = Variable Speed Fan with Fan Speed
Feedback
3 = Variable Speed Fan without Fan Speed
Feedback
4 = Single-Speed Fan – 2 Outputs
5 = Variable Speed Fan without Fan Speed
Feedback with Ambient Temp Offset
6 = Dual Fan
7 = Single-speed Fan – 1 Output
8 = Variable Speed Fan with Fan Speed
Feedback
9 = Variable Speed Fan without Fan Speed
Feedback with Ambient Temp Offset
255 = No Fan
255 – No Fan
VEPS, DRS
SW3
Con
fi
guration
17 = Single-speed
Fan or Two-speed
Fan Low
0 = No Function
17 = Single-speed Fan or Two-speed Fan
Low
0 = No Function
VEPS, DRS
PWM6
Con
fi
guration
5 = Two-speed
Fan High or
PWM Fan
0–= No Function
5 = Two-speed Fan High or PWM Fan
0 = No Function
VEPS, DRS
Table 5-33
Single-speed Fan – Type 4 MCM Options
All information subject to change without notice.