![Detroit Diesel DDEC VI Скачать руководство пользователя страница 307](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033307.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Parameter
Group
Parameter
Description
Options
Default
Access
31
Ambient Air
Temp Sensor
Enable
Con
fi
gures the
ambient air temp
sensor.
0 = Disabled
1 = Hardwired
2 = Reserved for J1939
3 = Reserved for J1587
4 = Reserved for ECAN
0 = Disabled
VEPS,
DRS
17
Lo Amb Air
Override
Temp
Extreme low
ambient air temp
to allow override.
-40°C – 75°C
-4°C
DDDL
7.0, DRS,
VEPS
17
Hi Amb Air
Override
Temp
Extreme high
ambient air temp
to allow override.
-40°C – 75°C
75°C
DDDL
7.0, DRS,
VEPS
17
Idle Shudown
Auto Override
Enables auto
override of
Idle/PTO
Shutdown based
on ambient air
temperature.
0 = No automatic override
performed
1 = Automatic override performed
0 = No automatic
override
performed
DDDL
7.0, DRS,
VEPS
*Not supported in NAFTA
Table 5-49
Idle Shutdown Timer Programming Options