![Detroit Diesel DDEC VI Скачать руководство пользователя страница 190](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033190.webp)
INPUTS AND OUTPUTS
4.3.1
AGS2 BACKUP LAMP
This digital output is used for non-multiplexed applications with the AGS2 transmission.
Installation
This digital output circuit is designed to sink no more that 2.0 A (DC) current.
The AGS2 Backup Lamp is wired to pin 3/9 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-28.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
3 09 DO
Selection
2 – AGS2 Backup
Lamp
0 – Disabled
1 — Grid Heater Hard Wired*
2 – AGS2 Backup Lamp
3 – Engine Brake Active
4 – Not Used
5 — FUSO Engine Brake
Active Lamp*
0 – Disabled
VEPS or
DRS
35
3 09 DO Fault
Detection
—
0 – Disabled
1 – Enabled
0 – Disabled
VEPS or
DRS
* Not supported in NAFTA
Table 4-28
AGS2 Backup Lamp Programming Options
4-30
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION