HARDWARE AND WIRING
6. Push the contact into the grommet until a positive stop is felt. See Figure 3-15. A slight
tug will con
fi
rm that it is properly locked into place. See Figure 3-16.
Figure 3-16
Locking Terminal Into Connector
Deutsch Terminal Removal
The appropriate size removal tool should be used when removing cables from connectors. The
proper removal tools are listed in Table 3-92.
Tool
Kent-Moore Part Number
Removing (12 AWG)
J–37451
Removing (16-18 AWG)
J–34513-1
Table 3-92
Removal Tools for Deutsch Terminals
3-76
All information subject to change without notice.