DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
ETC2 – Electronic Transmission Controller #2
Reception Rate :
100 ms
Data Length:
8 bytes
Data Page:
0
PDU format:
240
PDU speci
fi
c:
5
Default priority:
6
PGN:
61,445 (0x00F005)
Byte : 1
Transmission Selected Gear (SPN 524)
Resolution:
1 Gear Value / Bit, –125 Offset
Byte: 2,3
Transmission Actual Gear Ratio – N/A
Byte: 4
Transmission Current Gear (SPN 523)
Resolution:
1 Gear Value/Bit, – 125 Offset
Byte: 5-6
Transmission Requested Range – N/A
Byte: 7-8
Transmission Current Range – N/A
All information subject to change without notice.
(Rev. 01/07)
6-55