DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
5.8.3
PROGRAMMING FLEXIBILITY
DDEC VI is programmed with pressure, temperature, and level protection limits for each
parameter monitored. Rampdown is always enabled. Shutdown can be con
fi
gured for certain
parameters.
DDEC VI engine protection system parameters are listed in Table 5-31 .
Parameter
Group
Parameter
Description
Options
Default
Access
18
Coolant Temp Eng
Protect Shtn
Enable/Disable
shutdown for
high coolant
temperature
0 = Warning
1 = Engine Shutdown
1 = Engine
Shutdown
DDDL
7.0,
DRS,
VEPS
18
Coolant Level Eng
Protect Shtn
Enable/Disable
shutdown for low
coolant level
0 = Warning
1 = Engine Shutdown
1 = Engine
Shutdown
DDDL
7.0,
DRS,
VEPS
18
Oil Press Eng
Protect Shtn
Enable/Disable
shutdown for low
oil pressure
0 = Warning
1 = Engine Shutdown
1 = Engine
Shutdown
DDDL
7.0,
DRS,
VEPS
18
Oil Level Eng
Protect Shtn
Enable/Disable
shutdown for low
oil level
0 = Warning
1 = Engine Shutdown
1 = Engine
Shutdown
DDDL
7.0,
DRS,
VEPS
Table 5-31
Engine Protection
All information subject to change without notice.
(Rev. 01/07)
5-47
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION