![Detroit Diesel DDEC VI Скачать руководство пользователя страница 239](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033239.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
CPC
Parameter
Group
Parameter
Description
Options
Setting
Access
10
Stage 2
Factor Engine
Brake
Factor
determines
the amount
of medium
braking
0 – 100%
100
VEPS or
DRS
10
Stage 3 Mask
Engine Brake
Mask
determines
which device
turns on for
high braking
0 = No Engine Brake
16 = Exhaust Flap Only
17 = Jake Brake 2nd Stage
64 = Decompression Valve Only or Jake
Brake 1st Stage
80 = Decompression Valve & Exhaust
Flap
81 = Decompression Valve & Brake Gate
or Jake Brake 3rd Stage
0
VEPS or
DRS
10
Stage 3
Factor Engine
Brake
Factor
determines
the amount of
high braking
0 – 100%
100
VEPS or
DRS
10
Trans Mask
Engine Brake
—
0 = No Engine Brake
16 = Exhaust Flap Only
17 = Jake Brake 2nd Stage
64 = Decompression Valve Only or Jake
Brake 1st Stage
80 = Decompression Valve & Exhaust
Flap
81 = Decompression Valve & Brake Gate
or Jake Brake 3rd Stage
64
VEPS or
DRS
10
Trans Factor
Engine Brake
Factor
determines
the amount of
high braking
0–100%
100
VEPS or
DRS
13
4 18 DI
Selection
(Optional)
—
0 = Disable
1 = Enable Engine Door Bus*
2 = Enable Engine Hood Tilt Switch
3 = AGS2 PTO Feedback
4 = RPM Freeze
5 = Engine Brake Disable
6 = Fast Engine Heat-up Switch
0 =
Disable
VEPS or
DRS
13
Engine Brake
Switch Con
fi
g
—
0 = Hardwired
1 = Info from J1939
255 = No Available
0 = Hard-
wired
VEPS or
DRS
All information subject to change without notice.
(Rev. 01/07)
5-27
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION