![Detroit Diesel DDEC VI Скачать руководство пользователя страница 398](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033398.webp)
COMMUNICATION PROTOCOLS
PID 234
- Software Identi
fi
cation
update rate:
On Request only
format:
PID
Data
234
n
Byte: 1
Number of SW ID
fi
elds
Byte: 2
1st digit of major_num (ASCII)
Byte: 3
2nd digit of major_num (ASCII)
Byte: 4
3rd digit of major_num (ASCII)
Byte: 5
* delimiter (ASCII)
Byte: 6
1st digit of minor_num (ASCII)
Byte: 7
2nd digit of minor_num (ASCII)
Byte: 8
3rd digit of minor_num (ASCII)
Byte: 9
* delimiter (ASCII)
Byte: 10
1st digit of edit_ver (ASCII)
Byte: 11
2nd digit of edit_ver (ASCII)
Byte: 12
3rd digit of edit_ver (ASCII)
Byte: 13
* delimiter (ASCII)
Byte: 14
1st digit of con
fi
g_id (ASCII)
Byte: 15
2nd digit of con
fi
g_id (ASCII)
Byte: 16
3rd digit of con
fi
g_id (ASCII)
Byte: 17
* delimiter (ASCII)
Byte: 18
rel_type (ASCII)
Byte: 19
* delimiter (ASCII)
Byte: 20
hw_ver
Byte: 21
* delimiter (ASCII)
Byte: 22
edit_let (ASCII)
Byte: 23
* delimiter (ASCII)
Byte: 24
1st digit of diag_ver(ASCII)
Byte: 25
2nd digit of diag_ver(ASCII)
Byte: 26
3rd digit of diag_ver(ASCII)
Byte: 27
* delimiter (ASCII)
Byte: 28
1st digit of diag_variant(ASCII)
Byte: 29
2nd digit of diag_variant(ASCII)
Byte: 30
3rd digit of diag_variant(ASCII)
Byte: 31
* delimiter (ASCII)
Byte: 32
1st digit sw_year (ASCII)
Byte: 33
2nd digit sw_year (ASCII)
Byte: 34
* delimiter (ASCII)
Byte: 35
1st digit sw_month (ASCII)
Byte: 36
2nd digit sw_month (ASCII)
Byte: 37
* delimiter (ASCII)
Byte: 38
1st digit sw_day (ASCII)
6-22