![Detroit Diesel DDEC VI Скачать руководство пользователя страница 135](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033135.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
3.6.4
ENGINE COOLANT LEVEL SENSOR
The ECL Sensor provides an input to the engine protection system and warn the operator if a
low coolant level has been reached.
NOTE:
This sensor is required.
The main component of the ECL Sensor consists of a conductivity probe, which connects to
the CPC (see Figure 3-28).
NOTICE:
The probe has an operational temperature range of -40 to 257°F
(-40 to 125°C). Exposure to temperatures beyond this range
may result in unacceptable component life, or degraded sensor
accuracy.
Figure 3-28
Engine Coolant Level Sensor Speci
fi
cations
The connector listed in Table 3-102 is a Metri-Pack 280 series push-to-seat connector.
Coolant Level Sensor Connector
Connector
P/N: 15300027
Terminal
P/N: 12077411
Seal
P/N: 12015323
Secondary Lock
P/N: 15300014
Table 3-102
Metri-Pack 280 Connectors and Part Numbers
All information subject to change without notice.
(Rev. 01/07)
3-97
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION