![Detroit Diesel DDEC VI Скачать руководство пользователя страница 440](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033440.webp)
COMMUNICATION PROTOCOLS
PTO – Power Takeoff Information
Transmission Rate :
100 ms
Data Length:
8 bytes
Data Page:
0
PDU format:
254
PDU speci
fi
c:
240
Default priority:
6
PGN:
65,264 (0x00FEF0)
Byte: 1
Power Takeoff Oil Temperature - N/A
Byte: 2,3
Power Takeoff Speed - N/A
Byte: 4,5
Power Takeoff Set Speed (SPN 187)
Resolution:
0.125 rpm / Bit, 0 rpm offset
Byte: 6
Measured_PTO_1
Bits: 8,7
Not De
fi
ned
Bits: 6,5
Remote PTO Variable Speed Control Switch - N/A
Bits: 4,3
Remote PTO Preprogrammed Speed Control Switch
(SPN 979)
00: Switch Off
01: Switch On
11: Not Con
fi
gured
Bits: 2,1
PTO Enable Switch (SPN 980)
00: Switch Off
01: Switch On
11: Not Con
fi
gured
Byte: 7
Measured_PTO_2
Bits: 8,7
PTO Accelerate Switch (SPN 981)
00: Switch Off
01: Switch On
11: Not Con
fi
gured
Bits: 6,5
PTO Resume Switch (SPN 982)
00: Switch Off
01: Switch On
11: Not Con
fi
gured
Bits: 4,3
PTO Coast/Decelerate Switch (SPN 983)
00: Switch Off
01: Switch On
11: Not Con
fi
gured
Bits: 2,1
PTO Set Switch (SPN 984)
00: Switch Off
01: Switch On
11: Not Con
fi
gured
Byte: 8
Not De
fi
ned
6-64
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION