![Detroit Diesel DDEC VI Скачать руководство пользователя страница 276](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033276.webp)
FEATURES
5.11.5
TWO-SPEED FAN
This con
fi
guration uses two digital outputs, Fan Control #1 and Fan Control #2, to drive a
two-speed fan. When Fan Control #1 output is open, the fan operates in low-speed mode. When
Fan Control #1 and Fan Control #2 are both open, the fan operates in high-speed mode.
NOTE:
Fan output circuits are designed to sink no more than 2.0 A (DC) current.
Fan Control #1 is an open circuit when at least one of the following conditions occur:
□
Coolant temperature above factory set levels
□
Intake manifold air temperature above factory set levels
Fan control #2 is an open circuit when one of the following conditions occur:
□
Coolant temperature above factory set levels
□
Intake manifold air temperature above factory set levels
□
Coolant, or intake manifold air temperature sensor fails
□
Air conditioner is active (OEM supplied A/C switch is opened) – optional
□
Engine Brake level is active at high level
□
Fan control override switch is enabled
□
PTO enabled and active – optional
5-64
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION