DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.1.16
OPTIMIZED IDLE THERMOSTAT
The OI thermostat input indicates when the engine should run to heat/cool the cab when operating
in Optimized Idle mode. This input is normally open.
Installation
The OI thermostat is wired to the CPC on pin 3/1.
Programming Requirements and Flexibility
The options for this digital input are listed in Table 4-15.
Parameter
Group
Parameter
Options
Default
Access
13
3 01 AI Selection
0 = No Sensor
1 = Air Filter Restriction Sensor*
2 = OI Thermostat
3 = FUSO Clutch Pedal Sensor
Input*
0 = No Sensor
VEPS, DRS
* Not supported in NAFTA
Table 4-15
OI Thermostat Programming Options
All information subject to change without notice.
(Rev. 01/07)
4-17