Chapter 12 Descriptions of Parameter Settings | IED-S
12-03-9
DLS3 Over-speed Protection
Default:
50
Settings 0–100%
0: No protection
1–100%: percentage of rated speed
When elevator runs downward detection, it starts speed detection 0.5 sec. after DLS3 (Third one
downward forced deceleration) activates if there is no DLS4, and starts speed detection once
DLS3 activates if there is DLS4. If the speed detected is larger than Pr.03-42, fault code F199
(DLS3 Over-speed) occurs. The elevator stops urgently and automatically resets after 60
seconds.
ULS4 Over-speed Protection
Default:
50
Settings 0–100%
0: No protection
1–100%: percentage of rated speed
When elevator runs upward detection, it starts speed detection 0.5 sec. after ULS4 (Fourth one
upward forced deceleration) activates. If the speed detected is larger than Pr.03-43, fault code
F197 (ULS4 Over-speed) occurs. The elevator stops urgently and automatically resets after 60
seconds.
DLS4 Over-speed Protection
Default:
50
Settings 0–100%
0: No protection
1–100%: percentage of rated speed
When elevator runs downward detection, it starts speed detection 0.5 sec. after DLS4 (Fourth
one downward forced deceleration) activates. If the speed detected is larger than Pr.03-42, fault
code F198 (DLS4 Over-speed) occurs. The elevator stops urgently and automatically resets after
60 seconds.
Car Call Password
Default:
0
Settings 0–65535
0: No protection
1–100%: percentage of rated speed
When Pr.03-45 (Car Call Password) is not set to 0 (no 0 in the password code), and MI=203
PASSWORD (password car call) is ON, you must press the same value as set in Pr.03-45 for the
car call button on car call board for car call, and then press the desired floor button. At this time,
car call is registered. The car call button at the bottom floor is equal to 1. The interval between
each button pressed should be less than two seconds.
To modify the car call password, you can choose either:
1. Use built-in keypad or digital keypad KPC-CC01 to modify Pr.03-45 (Car Call Password).
2. Activate MI=204 PASSSET (Execute password setting) first. Then, use car call button settings
on car call board to change or cancel Pr.03-45 (Car Call Password).
To cancel car call password, press door closing button for five times to set Pr.03-45 (Car Call
Password) to 0.
Four-digit password setting: Press door closing button for one time first, and then use car call
button to set four-digit password.
Five-digit password setting: Use car call button to set.
Floor Display under Inspection
Default:
0
Settings 0–1
0: Does not display floor when in inspection mode
1: Displays floor when in inspection mode
Содержание IED-S Series
Страница 3: ......
Страница 10: ...Chapter 1 Introduction IED S 1 3 1 2 Model Name 1 3 Serial Number...
Страница 24: ...Chapter 2 Installation IED S 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Страница 25: ...Chapter 2 Installation IED S 2 6 The page intentionally left blank...
Страница 29: ...Chapter 3 Wiring IED S 3 4 IED S Integrated Elevator Drive System Wiring Diagram 01 System Configuration...
Страница 32: ...Chapter 3 Wiring IED S 3 7...
Страница 35: ...Chapter 3 Wiring IED S 3 10 3 3 Related Wiring Diagrams 03 Main Circuit for Drive Control Synchronous...
Страница 36: ...Chapter 3 Wiring IED S 3 11 04 Main Circuit for Drive Control Asynchronous...
Страница 38: ...Chapter 3 Wiring IED S 3 13 06 Safety Hatch...
Страница 39: ...Chapter 3 Wiring IED S 3 14 07 Brake Circuit...
Страница 40: ...Chapter 3 Wiring IED S 3 15 08 Inspection Circuit Cartop Inspection Connected to IED S Control Board...
Страница 42: ...Chapter 3 Wiring IED S 3 17 10 Input Contacts of Main Control Board for the Control Panel...
Страница 43: ...Chapter 3 Wiring IED S 3 18 11 Output Contacts of Main Control Board for the Control Panel...
Страница 44: ...Chapter 3 Wiring IED S 3 19 12 Contacts of Cartop Board OCB...
Страница 45: ...Chapter 3 Wiring IED S 3 20 13 Maneuvering Box 1 16 Floor ICB...
Страница 46: ...Chapter 3 Wiring IED S 3 21 14 1 Hall Call System...
Страница 50: ...Chapter 3 Wiring IED S 3 25 15 Lighting Circuit...
Страница 51: ...Chapter 3 Wiring IED S 3 26 16 UCMP Board Three Sensors DZU FL1 and DZD...
Страница 52: ...Chapter 3 Wiring IED S 3 27 17 UCMP Board Four Sensors DZU FL1 FL2 and DZD...
Страница 66: ...Chapter 5 Control Terminals IED S 5 1 Chapter 5 Control Terminals 5 1 Control Terminal Specifications...
Страница 67: ...Chapter 5 Control Terminals IED S 5 2 5 1 Control Terminal Specifications...
Страница 73: ...Chapter 5 Control Terminals IED S 5 8 The page intentionally left blank...
Страница 115: ...Chapter 6 Optional Accessories IED S 6 42 EMC Filter Model No B84143D0075R127 B84143D0090R127 Unit mm inch...
Страница 116: ...Chapter 6 Optional Accessories IED S 6 43 EMC Filter Model No B84143D0150R127 Unit mm inch...
Страница 117: ...Chapter 6 Optional Accessories IED S 6 44 EMC Filter Model No B84143D0200R127 Unit mm inch...
Страница 118: ...Chapter 6 Optional Accessories IED S 6 45 EMC Filter Model No B84142A0042R122 Unit mm inch...
Страница 123: ...Chapter 6 Optional Accessories IED S 6 50 The page intentionally left blank...
Страница 143: ...Chapter 7 Option Cards IED S 7 20 The page intentionally left blank...
Страница 151: ...Chapter 9 Digital Keypad IED S 9 4 Keypad Operation Process...
Страница 176: ...Chapter 10 Auto tuning Process IED S 10 9 10 3 2 Default Settings for Output Contacts of IED S Main Control Board...
Страница 177: ...Chapter 10 Auto tuning Process IED S 10 10 10 3 3 Default Settings for Contacts of IED S Cartop Board...
Страница 201: ...Chapter 10 Auto tuning Process IED S 10 34 The page intentionally left blank...
Страница 249: ...Chapter 11 Summary of Parameter Settings IED S 11 48 The page intentionally left blank...
Страница 263: ...Chapter 12 Descriptions of Parameter Settings IED S 12 00 14 The page intentionally left blank...
Страница 273: ...Chapter 12 Descriptions of Parameter Settings IED S 12 01 10 The page intentionally left blank...
Страница 281: ...Chapter 12 Descriptions of Parameter Settings IED S 12 02 8 The page intentionally left blank...
Страница 307: ...Chapter 12 Descriptions of Parameter Settings IED S 12 05 6 The page intentionally left blank...
Страница 319: ...Chapter 12 Descriptions of Parameter Settings IED S 12 06 12 The page intentionally left blank...
Страница 325: ...Chapter 12 Descriptions of Parameter Settings IED S 12 07 6 The page intentionally left blank...
Страница 345: ...Chapter 12 Descriptions of Parameter Settings IED S 12 10 8 The page intentionally left blank...
Страница 349: ...Chapter 12 Descriptions of Parameter Settings IED S 12 11 4 The page intentionally left blank...
Страница 359: ...Chapter 12 Descriptions of Parameter Settings IED S 12 12 10 The page intentionally left blank...
Страница 375: ...Chapter 12 Descriptions of Parameter Settings IED S 12 13 16 The page intentionally left blank...
Страница 381: ...Chapter 13 Warning Codes IED S 13 6 The page intentionally left blank...
Страница 415: ...Appendix A Single phase Application IED S A 4 The page intentionally left blank...
Страница 417: ...Appendix B Revision History IED S B 2 The page intentionally left blank...