Chapter 8 Specifications | IED-S
8-2
8-1 230V Series
Frame Size
C
D
Model IED-_ _ _S21/23A
055
075
110
150
185
220
Applicable Motor Output (kW)
5.5
7.5
11 15 18.5 22
Applicable Motor Output (HP)
7.5
10
15 20 25 30
Output Rating
Rated Output Capacity (kVA)
9.5
12.5
19 25 29 34
Rated Output Current (A)
24
30
45 58 77 87
Maximum Output Voltage (V)
Proportional to input voltage
Output Frequency Range (Hz)
0.00–400.00
Carrier Frequency Range (kHz)
2–15
Rated Output Maximum Carrier
Frequency (kHz)
10 8
Input Rating
Input
Current
(A)
23 30 47 56 73 90
Rated Voltage (V)
200–240 / Three-phase
Rated Frequency (Hz)
50/60
Allowed Voltage Tolerance (V)
±10% (180–264)
Allowed Frequency Tolerance (Hz)
±5% (47–63)
Cooling Method
Fan cooling
Weight
(kg)
8 10 10 13 13 13
NOTE: For single-phase models, see
Appendix A Single-phase Applications
.
8-2 460V Series
Frame Size
C
D
E
Model IED-_ _ _S43A
055 075 110 150 185 220 300 370 450 550 750
Applicable Motor Output (kW)
5.5
7.5 11 15
18.5
22 30 37 45 55 75
Applicable Motor Output (HP)
7.5 10 15 20 25 30 40 50 60 75 100
Output Rating
Rated Output Capacity (kVA)
10.4 13.5 18.3 24 30.3 36 46.2 63.7 80 96.4 116.3
Rated Output Current (A)
13 17 23 30 38 45 58 80 100 128 165
Maximum Output Voltage (V)
Proportional to input voltage
Output Frequency Range (Hz)
0.00–400.00
Carrier Frequency Range (kHz)
2–15 2–9
2–6
Rated Output Maximum Carrier
Frequency (kHz)
10 8
6
Input Rating
Input Current (A)
14
17 24 30 37 47 58 80 100 128 165
Rated Voltage (V)
380–480 / Three-phase
Rated Frequency (Hz)
50 / 60
Allowed Voltage Tolerance (V)
±10% (342–528)
Allowed Frequency Tolerance
(Hz)
±5% (47–63)
Cooling Method
Fan cooling
Weight (kg)
8 10 10 10 10 13 14.5 36 36 50 50
NOTE:
Input/output current rating in the table above varies with the actual input reactor, transformer, wiring connections and
power supply impedance.
Содержание IED-S Series
Страница 3: ......
Страница 10: ...Chapter 1 Introduction IED S 1 3 1 2 Model Name 1 3 Serial Number...
Страница 24: ...Chapter 2 Installation IED S 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Страница 25: ...Chapter 2 Installation IED S 2 6 The page intentionally left blank...
Страница 29: ...Chapter 3 Wiring IED S 3 4 IED S Integrated Elevator Drive System Wiring Diagram 01 System Configuration...
Страница 32: ...Chapter 3 Wiring IED S 3 7...
Страница 35: ...Chapter 3 Wiring IED S 3 10 3 3 Related Wiring Diagrams 03 Main Circuit for Drive Control Synchronous...
Страница 36: ...Chapter 3 Wiring IED S 3 11 04 Main Circuit for Drive Control Asynchronous...
Страница 38: ...Chapter 3 Wiring IED S 3 13 06 Safety Hatch...
Страница 39: ...Chapter 3 Wiring IED S 3 14 07 Brake Circuit...
Страница 40: ...Chapter 3 Wiring IED S 3 15 08 Inspection Circuit Cartop Inspection Connected to IED S Control Board...
Страница 42: ...Chapter 3 Wiring IED S 3 17 10 Input Contacts of Main Control Board for the Control Panel...
Страница 43: ...Chapter 3 Wiring IED S 3 18 11 Output Contacts of Main Control Board for the Control Panel...
Страница 44: ...Chapter 3 Wiring IED S 3 19 12 Contacts of Cartop Board OCB...
Страница 45: ...Chapter 3 Wiring IED S 3 20 13 Maneuvering Box 1 16 Floor ICB...
Страница 46: ...Chapter 3 Wiring IED S 3 21 14 1 Hall Call System...
Страница 50: ...Chapter 3 Wiring IED S 3 25 15 Lighting Circuit...
Страница 51: ...Chapter 3 Wiring IED S 3 26 16 UCMP Board Three Sensors DZU FL1 and DZD...
Страница 52: ...Chapter 3 Wiring IED S 3 27 17 UCMP Board Four Sensors DZU FL1 FL2 and DZD...
Страница 66: ...Chapter 5 Control Terminals IED S 5 1 Chapter 5 Control Terminals 5 1 Control Terminal Specifications...
Страница 67: ...Chapter 5 Control Terminals IED S 5 2 5 1 Control Terminal Specifications...
Страница 73: ...Chapter 5 Control Terminals IED S 5 8 The page intentionally left blank...
Страница 115: ...Chapter 6 Optional Accessories IED S 6 42 EMC Filter Model No B84143D0075R127 B84143D0090R127 Unit mm inch...
Страница 116: ...Chapter 6 Optional Accessories IED S 6 43 EMC Filter Model No B84143D0150R127 Unit mm inch...
Страница 117: ...Chapter 6 Optional Accessories IED S 6 44 EMC Filter Model No B84143D0200R127 Unit mm inch...
Страница 118: ...Chapter 6 Optional Accessories IED S 6 45 EMC Filter Model No B84142A0042R122 Unit mm inch...
Страница 123: ...Chapter 6 Optional Accessories IED S 6 50 The page intentionally left blank...
Страница 143: ...Chapter 7 Option Cards IED S 7 20 The page intentionally left blank...
Страница 151: ...Chapter 9 Digital Keypad IED S 9 4 Keypad Operation Process...
Страница 176: ...Chapter 10 Auto tuning Process IED S 10 9 10 3 2 Default Settings for Output Contacts of IED S Main Control Board...
Страница 177: ...Chapter 10 Auto tuning Process IED S 10 10 10 3 3 Default Settings for Contacts of IED S Cartop Board...
Страница 201: ...Chapter 10 Auto tuning Process IED S 10 34 The page intentionally left blank...
Страница 249: ...Chapter 11 Summary of Parameter Settings IED S 11 48 The page intentionally left blank...
Страница 263: ...Chapter 12 Descriptions of Parameter Settings IED S 12 00 14 The page intentionally left blank...
Страница 273: ...Chapter 12 Descriptions of Parameter Settings IED S 12 01 10 The page intentionally left blank...
Страница 281: ...Chapter 12 Descriptions of Parameter Settings IED S 12 02 8 The page intentionally left blank...
Страница 307: ...Chapter 12 Descriptions of Parameter Settings IED S 12 05 6 The page intentionally left blank...
Страница 319: ...Chapter 12 Descriptions of Parameter Settings IED S 12 06 12 The page intentionally left blank...
Страница 325: ...Chapter 12 Descriptions of Parameter Settings IED S 12 07 6 The page intentionally left blank...
Страница 345: ...Chapter 12 Descriptions of Parameter Settings IED S 12 10 8 The page intentionally left blank...
Страница 349: ...Chapter 12 Descriptions of Parameter Settings IED S 12 11 4 The page intentionally left blank...
Страница 359: ...Chapter 12 Descriptions of Parameter Settings IED S 12 12 10 The page intentionally left blank...
Страница 375: ...Chapter 12 Descriptions of Parameter Settings IED S 12 13 16 The page intentionally left blank...
Страница 381: ...Chapter 13 Warning Codes IED S 13 6 The page intentionally left blank...
Страница 415: ...Appendix A Single phase Application IED S A 4 The page intentionally left blank...
Страница 417: ...Appendix B Revision History IED S B 2 The page intentionally left blank...