70
About Your System
Error: Memory
failure detected.
Memory size
reduced. Replace
the faulty DIMM as
soon as possible.
Faulty or improperly
seated memory modules.
See "Troubleshooting Blade
Memory" on page 191.
Error programming
flexAddress (MAC)
for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
Error programming
flexAddress (iSCSI
MAC) for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
Error resetting
NIC after
programming
flexAddress for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
FBD training
error: The
following branch
has been disabled:
Branch
x
.
The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.
Ensure that only Dell
qualified memory is used.
Dell recommends
purchasing memory upgrade
kits directly from
http://www.dell.com
or your
Dell sales agent to ensure
compatibility.
Gate A20 failure.
Faulty keyboard controller
(faulty blade board).
See "Getting Help" on
page 217.
General failure.
Operating system
corrupted or improperly
installed.
Reinstall the operating
system.
Table 1-18.
Blade Messages
(continued)
Message
Causes
Corrective Actions
Содержание PowerEdge M600
Страница 10: ...10 Contents 8 Getting Help 217 Contacting Dell 217 Glossary 219 Index 231 ...
Страница 50: ...50 About Your System Figure 1 16 Example of Full Height Blade Port Mapping Blade 3 ...
Страница 52: ...52 About Your System Figure 1 17 Example of Half Height Blade Port Mapping ...
Страница 156: ...156 Installing Blade Components ...
Страница 178: ...178 Installing Enclosure Components ...
Страница 202: ...202 Running System Diagnostics ...
Страница 216: ...216 System Board Information ...
Страница 218: ...218 Getting Help ...
Страница 236: ...236 Index ...