Replacing the BOSS card
To replace the BOSS card, perform the tasks in the following checklist in the order
they are listed.
The BOSS card is a simple RAID solution card designed specifically for booting a
server's operating system. The card supports up to two 6 Gbps M.2 SATA drives. The
BOSS adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available in both
the low-profile and full-height form factor.
Note
Before starting this FRU procedure, familiarize yourself with the topics in
information before performing a FRU procedure
CAUTION
This FRU procedure requires you to perform mandatory software tasks in VxFlex
OS, as described in the
VxFlex Ready Node Field Replacement Unit Software Guide
.
You will be referred to these mandatory software tasks in the following checklist.
Check
List
Task
Topic
☐
1
Identify the faulty part.
System diagnostics and indicator
on page 203.
Perform mandatory software tasks to prepare the node for part replacement:
☐
2
Gracefully shut down the node.
See "Gracefully shut down the node" in
the VxFlex Ready Node Field Replacement
Unit Software Guide
.
Return to this guide for instructions on replacing the system component:
☐
3
Prepare the replacement BOSS card.
Prepare the replacement BOSS card
on page 59.
☐
4
Remove the bezel.
on page
166.
☐
5
Disconnect the power cords and I/O
cables.
Disconnect the power cords and I/O
on page 164.
☐
6
Extend the system from the cabinet.
☐
7
Remove the system cover.
on page
173.
☐
8
Remove the faulty BOSS card from the
system.
☐
9
Migrate the M.2 modules to the
replacement BOSS card.
Transfer the M.2 modules to the
☐
10
Install the replacement BOSS card in the
system.
Install the BOSS card onto expansion
☐
11
Install the system cover.
173.
Hardware FRU procedures
58
VxFlex Ready Node R840
Hardware Field Replacement Unit and Service Manual