Figure 102 AC PSU status indicator
1. AC PSU status indicator/handle
This table describes the AC PSU status indicators and the condition of the PSU when
the power indicator light is green, blinking green, blinking amber, and when it is not lit.
Table 42 AC PSU status indicator codes
Power indicator codes
Condition
Green
A valid power source is connected to the PSU,
and the PSU is operational.
Blinking amber
Indicates a problem with the PSU.
Not illuminated
Power is not connected to the PSU.
Blinking green
When the firmware of the PSU is being
updated, the PSU handle blinks green.
CAUTION
Do not disconnect the power cable, or
unplug the PSU when updating firmware. If
firmware update is interrupted, the PSUs
do not function.
Blinking green and turns off
When hot-plugging a PSU, the PSU handle
blinks green five times at a rate of 4 Hz and
turns off. This indicates a PSU mismatch
concerning efficiency, feature set, health
status, or supported voltage.
CAUTION
If two PSUs are installed, both the PSUs
must have the same type of label; for
example, Extended Power Performance
(EPP) label. Mixing PSUs from previous
generations of VxFlex Ready Node servers
is not supported, even if the PSUs have the
same power rating. This results in a PSU
mismatch condition, or failure to turn on
the system.
System diagnostics and indicator codes
Power supply unit indicator codes
209
Содержание EMC VxFlex Ready Node R840
Страница 10: ...TABLES 10 VxFlex Ready Node R840 Hardware Field Replacement Unit and Service Manual ...
Страница 12: ...Notes cautions and warnings 12 VxFlex Ready Node R840 Hardware Field Replacement Unit and Service Manual ...
Страница 218: ...Getting help 218 VxFlex Ready Node R840 Hardware Field Replacement Unit and Service Manual ...