Disconnect the power cords and I/O cables
This procedure is used to disconnect the system from electrical power and disconnect
the peripherals.
Note
Before performing the following steps, ensure that the system is prepared for
removal. Use the management GUI to ensure that the system is not visible.
Procedure
1. Label each power cord and I/O cable so you can easily identify them when you
need to plug them in to restore the system.
2. Unplug power cords from the power supplies and disconnect the I/O cables
from the system.
Connect the I/O cables and power cords
This procedure is used to connect the peripherals and power to the system.
Procedure
1. Using the connection information recorded on the labels, connect the I/O
cables to the system.
2. Plug the power cords into the power supplies.
Extend the system from the cabinet
This procedure is used to extend the system from the cabinet so that the system
cover can be removed to access the internal FRU components, or used in removing
the system from the cabinet.
Procedure
1. At the front of the cabinet, locate the two rocker switches on left and right side
of the system. Press the top of the rocker switches inward to release the
system from the cabinet.
If the rocker switches do not disengage the system, loosen the screw under
each rocker.
2. Pull the system from the cabinet until the rails lock in the extended position.
Common procedures for replacing system components
164
VxFlex Ready Node R840
Hardware Field Replacement Unit and Service Manual