Figure 76. Removing the liquid cooling heat sink modules
Next steps
1. If you are uninstalling a faulty heat sink,
replace the liquid cooling heat sink modules
Removing the processor
Prerequisites
WARNING:
The heat sink may be hot to touch for some time after the system has been powered off. Allow the
heat sink to cool before removing it.
1. Follow the safety guidelines listed in the
.
2. Follow the procedure listed in the
Before working inside your system
3.
.
CAUTION:
You may find the CMOS battery loss or CMOS checksum error is displayed during the first instance
of powering on the system after the processor or system board replacement which is expected. To fix, go to set
up option to configure the system settings.
Steps
1. Using a Torx #T20 screwdriver, loosen the screws to release the force plate. The sequence to loosen the screws is 3, 2, and
1.
NOTE:
The screw numbers are marked on the force plate.
Installing and removing system components
81