3.
Click Apply, and then update all default time outs and maximum time out limits.
Configuring Services Using RACADM
To enable and configure the various services, use the following RACADM objects:
•
cfgRacTuning
•
cfgRacTuneRemoteRacadmEnable
For more information about these objects, see
RACADM Command Line Reference Guide for iDRAC7 and CMC
available
at dell.com/support/manuals.
If the firmware on the server does not support a feature, configuring a property related to that feature displays an error.
For example, using RACADM to enable remote syslog on an unsupported iDRAC displays an error message.
Similarly, when displaying the iDRAC properties using the RACADM getconfig command, the property values are
displayed as N/A for an unsupported feature on the server.
For example:
$ racadm getconfig -g cfgSessionManagement -m server-1
# cfgSsnMgtWebServerMaxSessions=N/A
# cfgSsnMgtWebServerActiveSessions=N/A
# cfgSsnMgtWebServerTimeout=N/A
# cfgSsnMgtSSHMaxSessions=N/A
# cfgSsnMgtSSHActiveSessions=N/A
# cfgSsnMgtSSHTimeout=N/A
# cfgSsnMgtTelnetMaxSessions=N/A
# cfgSsnMgtTelnetActiveSessions=N/A
# cfgSsnMgtTelnetTimeout=N/A
Configuring CMC Extended Storage Card
You can enable or repair the optional Removable Flash Media for use as an extended non-volatile storage. Some CMC
features depend on extended nonvolatile storage for their operation.
To enable or repair the Removable Flash Media using the CMC Web interface:
1.
In the System tree, go to Chassis Overview, and then click Chassis Controller
→
Flash Media. The Removable Flash
Media page is displayed.
2.
From the drop-down menu, select one of the following as required:
– Use flash media for storing chassis data
– Repair active controller media
– Begin replicating data between media
– Stop replicating data between media
– Stop using flash media for storing chassis data
For more information about these options, see the
CMC Online Help
.
3.
Click Apply to apply the selected option.
If two CMCs are present in the chassis, both CMCs must contain flash media. CMC features which depend on flash
media (except for Flexaddress) do not function properly until the Dell-authorized media is installed and enabled on
this page.
70
Содержание Chassis Management Controller
Страница 1: ...Dell Chassis Management Controller Firmware Version 4 3 User s Guide ...
Страница 42: ...42 ...
Страница 56: ...56 ...
Страница 84: ...84 ...
Страница 98: ...98 ...
Страница 104: ...104 ...
Страница 130: ...130 ...
Страница 136: ...136 ...
Страница 200: ...200 ...
Страница 214: ...214 ...