53-1001810-01
Configuring optional VSRP parameters
15
Specifying a track port
You can configure the VRID on one interface to track the link state of another interface on the
device. This capability is useful for tracking the state of the exit interface for the path for which the
VRID is providing redundancy. Refer to
“VSRP priority calculation”
on page 414.
To configure a VRID to track an interface, enter a command such as the following at the
configuration level for the VRID.
BigIron RX(config-vlan-200-vrid-1)# track-port e 2/4
Syntax: [no] track-port ethernet
<slot>/<portnum>
| ve <num> [priority
<num>
]
The priority
<num>
parameter changes the VSRP priority of the interface. If this interface goes
down, the VRID’s VSRP priority is reduced by the amount of the track port priority you specify here.
NOTE
The priority
<num>
option changes the priority of the specified interface, overriding the default track
port priority. To change the default track port priority, use the backup track-priority
<num>
command.
Disabling or re-enabling backup pre-emption
By default, a Backup that has a higher priority than another Backup that has become the Master
can preempt the Master, and take over the role of Master. If you want to prevent this behavior,
disable preemption.
Preemption applies only to Backups and takes effect only when the Master has failed and a
Backup has assumed ownership of the VRID. The feature prevents a Backup with a higher priority
from taking over as Master from another Backup that has a lower priority but has already become
the Master of the VRID.
Preemption is especially useful for preventing flapping in situations where there are multiple
Backups and a Backup with a lower priority than another Backup has assumed ownership, because
the Backup with the higher priority was unavailable when ownership changed.
If you enable the non-preempt mode (thus disabling the preemption feature) on all the Backups,
the Backup that becomes the Master following the disappearance of the Master continues to be
the Master. The new Master is not preempted.
To disable preemption on a Backup, enter a command such as the following at the configuration
level for the VRID.
BigIron RX(config-vlan-200-vrid-1)# non-preempt-mode
Syntax: [no] non-preempt-mode
Port transition hold timer
Using this VSRP command will delay the sending of port "up"/"down" events. This command affects
the physical link events. However, the resulting logical link events are also delayed. This is a
per-interface command.
For example, if VSRP is enabled on the port, the ownership would not change until the port status
has remained up or down for the configured amount of time to ensure that minor transient states
of a link do not unintentionally cause a disruptive topology change in the network.
Содержание Brocade DCX
Страница 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Страница 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Страница 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Страница 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Страница 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Страница 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Страница 566: ...494 BigIron RX Series Configuration Guide 53 1001810 01 QoS for the oversubscribed 16 x 10GE modules 18 ...
Страница 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Страница 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Страница 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Страница 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Страница 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Страница 926: ...854 BigIron RX Series Configuration Guide 53 1001810 01 Generalized TTL security mechanism support 26 ...
Страница 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Страница 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Страница 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Страница 998: ...926 BigIron RX Series Configuration Guide 53 1001810 01 Configuring BFD for the specified protocol 30 ...
Страница 1014: ...942 BigIron RX Series Configuration Guide 53 1001810 01 Displaying multi device port authentication information 31 ...
Страница 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Страница 1072: ...1000 BigIron RX Series Configuration Guide 53 1001810 01 IP source guard 35 Syntax show ip source guard ethernet port num ...
Страница 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Страница 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Страница 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Страница 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Страница 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Страница 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Страница 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...