BigIron RX Series Configuration Guide
1205
53-1001810-01
Configuring OSPFv3
48
For example, to change the dead interval to 60 seconds on the virtual links defined on ABR1 and
ABR2, enter the following command on ABR1.
BigIron RX(config-ospf6-router)# area 1 virtual-link 209.157.22.1
dead-interval 60
Enter the following command on ABR2.
BigIron RX(config-ospf6-router)# area 1 virtual-link 10.0.0.1 dead-interval 60
Syntax: area <
number
> | <
ipv4-address
> virtual-link
<router-id
> [dead-interval <s
econds
> |
hello-interval <
seconds
> | retransmit-interval <
seconds
> | transmit-delay <
seconds
>]
The area <number> | <
ipv4-address
> parameter specifies the transit area.
The <
router-id
> parameter specifies the router ID of the OSPF router at the remote end of the
virtual link. To display the router ID on a router, enter the show ip command.
The dead-interval, hello-interval, retransmit-interval, and transmit-delay parameters are discussed
earlier in this section.
Changing the reference bandwidth for the cost on OSPFv3 interfaces
Each interface on which OSPFv3 is enabled has a cost associated with it. The Brocade device
advertises its interfaces and their costs to OSPFv3 neighbors. For example, if an interface has an
OSPF cost of ten, the Brocade device advertises the interface with a cost of ten to other OSPF
routers.
By default, an interface’s OSPF cost is based on the port speed of the interface. The software uses
the following formula to calculate the cost.
Cost = reference-bandwidth/interface-speed
By default, the reference bandwidth is 100 Mbps. If the resulting cost is less than 1, the software
rounds the cost up to 1. The default reference bandwidth results in the following costs:
•
10 Mbps port’s cost = 100/10 = 10
•
100 Mbps port’s cost = 100/100 = 1
•
1000 Mbps port’s cost = 100/1000 = 0.10, which is rounded up to 1
•
155 Mbps port’s cost = 100/155 = 0.65, which is rounded up to 1
•
622 Mbps port’s cost = 100/622 = 0.16, which is rounded up to 1
•
2488 Mbps port’s cost = 100/2488 = 0.04, which is rounded up to 1
The bandwidth for interfaces that consist of more than one physical port is calculated as follows:
•
Trunk group – The combined bandwidth of all the ports.
•
Virtual (Ethernet) interface – The combined bandwidth of all the ports in the port-based VLAN
that contains the virtual interface.
You can change the default reference bandwidth from 100 Mbps to a value from 1 – 4294967
Mbps.
If a change to the reference bandwidth results in a cost change to an interface, the Brocade device
sends a link state update to update the costs of interfaces advertised by the Brocade device.
Содержание Brocade DCX
Страница 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Страница 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Страница 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Страница 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Страница 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Страница 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Страница 566: ...494 BigIron RX Series Configuration Guide 53 1001810 01 QoS for the oversubscribed 16 x 10GE modules 18 ...
Страница 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Страница 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Страница 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Страница 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Страница 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Страница 926: ...854 BigIron RX Series Configuration Guide 53 1001810 01 Generalized TTL security mechanism support 26 ...
Страница 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Страница 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Страница 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Страница 998: ...926 BigIron RX Series Configuration Guide 53 1001810 01 Configuring BFD for the specified protocol 30 ...
Страница 1014: ...942 BigIron RX Series Configuration Guide 53 1001810 01 Displaying multi device port authentication information 31 ...
Страница 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Страница 1072: ...1000 BigIron RX Series Configuration Guide 53 1001810 01 IP source guard 35 Syntax show ip source guard ethernet port num ...
Страница 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Страница 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Страница 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Страница 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Страница 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Страница 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Страница 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...