300
BigIron RX Series Configuration Guide
53-1001810-01
Configuring 802.1q-in-q tagging
11
As shown in
Figure 25
, the ports to customer interfaces are untagged, whereas the uplink ports to
the provider cloud are tagged, because multiple client VLANs share the uplink to the provider cloud.
In this example, the device treats the customer’s private VLAN ID and 8100 tag type as normal
payload, and adds the 9100 tag type to the packet when the packet is sent to the uplink and
forwarded along the provider cloud.
As long as the switches in the provider’s network support the 9100 tag type, the data gets switched
along the network. However, devices that do not support the 9100 tag type may not properly
handle the packets.
Figure 26
shows an example application of the 802.1Q-in-Q enhancement.
FIGURE 26
802.1Q-in-Q configuration example
In
Figure 26
, the untagged ports (to customer interfaces) accept frames that have any 802.1Q
tag other than the configured tag-type 9100. These packets are considered untagged on this
incoming port and are re-tagged when they are sent out of the uplink towards the provider. The
802.1Q tag-type on the uplink port is 8100, so the device will switch the frames to the uplink
device with an additional 8100 tag, thereby supporting devices that only support this method
of VLAN tagging.
Configuration rules
Follow the rules below when configuring 802.1q-in-q tagging:
•
Since the uplink (to the provider cloud) and the edge link (to the customer port) must have
different 802.1Q tags, make sure the uplink and edge link are in different port regions.
•
If you configure a port with an 802.1Q tag-type, the device automatically applies the 802.1Q
tag-type to all ports within the same port region.
•
If you remove the 802.1Q tag-type from a port, the device automatically removes the 802.1Q
tag-type from all ports within the same port region.
•
The device supports on configured tag-type per device, along with the default tag-type of 8100.
For example, if you configure an 802.1Q tag of 9100 on ports 1 – 8, then later configure an
802.1Q tag of 5100 on port 9, the device automatically applies the 5100 tag to all ports in the
same port region as port 9, and also changes the 802.1Q tag-type on ports 1 – 8 to 5100.
Enabling 802.1Q-in-Q tagging
To enable the 802.1Q-in-Q feature, configure an 802.1Q tag type on the untagged edge links (the
customer ports) to any value other than the 802.1Q tag for incoming traffic.
To customer interface
Provider
Edge Switch
Uplink to provider cloud
Untagged
Tagged
DA
SA
8100
Customer
VLAN
DA
SA
8100
Customer
VLAN
Provider
VLAN
8100
Configured tag-type 9100
Default tag-type 8100
Содержание Brocade DCX
Страница 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Страница 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Страница 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Страница 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Страница 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Страница 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Страница 566: ...494 BigIron RX Series Configuration Guide 53 1001810 01 QoS for the oversubscribed 16 x 10GE modules 18 ...
Страница 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Страница 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Страница 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Страница 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Страница 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Страница 926: ...854 BigIron RX Series Configuration Guide 53 1001810 01 Generalized TTL security mechanism support 26 ...
Страница 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Страница 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Страница 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Страница 998: ...926 BigIron RX Series Configuration Guide 53 1001810 01 Configuring BFD for the specified protocol 30 ...
Страница 1014: ...942 BigIron RX Series Configuration Guide 53 1001810 01 Displaying multi device port authentication information 31 ...
Страница 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Страница 1072: ...1000 BigIron RX Series Configuration Guide 53 1001810 01 IP source guard 35 Syntax show ip source guard ethernet port num ...
Страница 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Страница 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Страница 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Страница 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Страница 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Страница 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Страница 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...