962
BigIron RX Series Configuration Guide
53-1001810-01
Configuring 802.1x port security
33
•
Tunnel-Type (64) – RFC 2868
•
Tunnel-Medium-Type (65) – RFC 2868
•
EAP Message (79) – RFC 2579
•
Tunnel-Private-Group-Id (81) – RFC 2868
Configuring dynamic VLAN assignment for 802.1x ports
Brocade
’s 802.1x implementation supports assigning a port to a VLAN dynamically, based on
information received from an Authentication (RADIUS) Server. If one of the attributes in the
Access-Accept message sent by the RADIUS server specifies a VLAN identifier, and this VLAN
matches a VLAN on the
BigIron RX
device, the client’s port is moved from its default VLAN to the
specified VLAN. When the client disconnects from the network, the port is placed back in its default
VLAN.
When a client/supplicant successfully completes the EAP authentication process, the
Authentication Server (the RADIUS server) sends the Authenticator (the
BigIron RX
) a RADIUS
Access-Accept message that grants the client access to the network. The RADIUS Access-Accept
message contains attributes set for the user in the user's access profile on the RADIUS server.
If one of the attributes in the Access-Accept message specifies a VLAN identifier, and this VLAN is
available on the device, the client’s port is moved from its default VLAN to the specified VLAN.
When the client disconnects from the network, the port is placed back in its default VLAN.
NOTE
This feature is supported on port-based VLANs only. This feature cannot be used to place an
802.1x-enabled port into a Layer 3 protocol VLAN.
To enable 802.1x VLAN ID support on the device, you must add the following attributes to a user’s
profile on the RADIUS server.
The device reads the attributes as follows:
•
If the Tunnel-Type or the Tunnel-Medium-Type attributes in the Access-Accept message do not
have the values specified above, the device ignores the three Attribute-Value pairs. The client
becomes authorized, but the client’s port is not dynamically placed in a VLAN.
•
If the Tunnel-Type or the Tunnel-Medium-Type attributes in the Access-Accept message do have
the values specified above, but there is no value specified for the Tunnel-Private-Group-ID
attribute, the client will not become authorized.
•
When the device receives the value specified for the Tunnel-Private-Group-ID attribute, it
checks whether the
<vlan-name>
string matches the name of a VLAN configured on the
device. If there is a VLAN on the device whose name matches the
<vlan-name>
, then the
client’s port is placed in the VLAN whose ID corresponds to the VLAN name.
TABLE 151
802.1x VLAN attributes required from the RADIUS server
Attribute name
Type
Value
Tunnel-Type
064
13 (decimal) – VLAN
Tunnel-Medium-Type
065
6 (decimal) – 802
Tunnel-Private-Group-ID
081
<vlan-name>
(string) – either the name or the number of a VLAN
configured on the
BigIron RX
.
Содержание Brocade DCX
Страница 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Страница 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Страница 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Страница 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Страница 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Страница 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Страница 566: ...494 BigIron RX Series Configuration Guide 53 1001810 01 QoS for the oversubscribed 16 x 10GE modules 18 ...
Страница 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Страница 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Страница 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Страница 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Страница 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Страница 926: ...854 BigIron RX Series Configuration Guide 53 1001810 01 Generalized TTL security mechanism support 26 ...
Страница 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Страница 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Страница 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Страница 998: ...926 BigIron RX Series Configuration Guide 53 1001810 01 Configuring BFD for the specified protocol 30 ...
Страница 1014: ...942 BigIron RX Series Configuration Guide 53 1001810 01 Displaying multi device port authentication information 31 ...
Страница 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Страница 1072: ...1000 BigIron RX Series Configuration Guide 53 1001810 01 IP source guard 35 Syntax show ip source guard ethernet port num ...
Страница 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Страница 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Страница 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Страница 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Страница 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Страница 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Страница 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...