BigIron RX Series Configuration Guide
933
53-1001810-01
Configuring multi-device port authentication
31
To enable dynamic VLAN assignment for authenticated MAC addresses, you must add the following
attributes to the profile for the MAC address on the RADIUS server (dynamic VLAN assignment on
multi-device port authentication-enabled interfaces is enabled by default and can be disabled).
Refer to
“Dynamic VLAN and ACL assignments”
on page 928 for a list of the attributes that must be
set on the RADIUS server
Dynamic VLAN assignment on a multi-device port authentication-enabled interface is enabled by
default. If it is disabled, enter commands such as the following command to enable it.
BigIron RX(config)# interface e 3/1
BigIron RX(config-if-e100-3/1)# mac-authentication enable-dynamic-vlan
Syntax: [no] mac-authentication enable-dynamic-vlan
If a previous authentication attempt for a MAC address failed, and as a result the port was placed
in the restricted VLAN, but a subsequent authentication attempt was successful, the RADIUS
Access-Accept message may specify a VLAN for the port. By default, the device moves the port out
of the restricted VLAN and into the RADIUS-specified VLAN. You can optionally configure the device
to ignore the RADIUS-specified VLAN in the RADIUS Access-Accept message, and leave the port in
the restricted VLAN.
To do this, enter the following command.
BigIron RX(config)# mac-authentication no-override-restrict-vlan
Syntax: [no] mac-authentication no-override-restrict-vlan
Notes:
•
For untagged ports, if the VLAN ID provided by the RADIUS server is valid, then the port is
removed from its current VLAN and moved to the RADIUS-specified VLAN as an untagged port.
•
If you configure dynamic VLAN assignment on a multi-device port authentication enabled
interface, and the Access-Accept message returned by the RADIUS server does not contain a
Tunnel-Private-Group-ID attribute, then it is considered an authentication failure, and the
configured authentication failure action is performed for the MAC address.
•
If the
<vlan-name>
string does not match either the name or the ID of a VLAN configured on
the device, then it is considered an authentication failure, and the configured authentication
failure action is performed for the MAC address.
•
If an untagged port had previously been assigned to a VLAN though dynamic VLAN assignment,
and then another MAC address is authenticated on the same port, but the RADIUS
Access-Accept message for the second MAC address specifies a different VLAN, then it is
considered an authentication failure for the second MAC address, and the configured
authentication failure action is performed. Note that this applies only if the first MAC address
has not yet aged out. If the first MAC address has aged out, then dynamic VLAN assignment
would work as expected for the second MAC address.
Specifying to which VLAN a port is moved after its RADIUS-specified
VLAN assignment expires
When a port is dynamically assigned to a VLAN through the authentication of a MAC address, and
the MAC session for that address is deleted on the BigIron RX device, then by default the port is
removed from its RADIUS-assigned VLAN and placed back in the VLAN where it was originally
assigned.
Содержание Brocade DCX
Страница 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Страница 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Страница 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Страница 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Страница 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Страница 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Страница 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Страница 566: ...494 BigIron RX Series Configuration Guide 53 1001810 01 QoS for the oversubscribed 16 x 10GE modules 18 ...
Страница 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Страница 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Страница 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Страница 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Страница 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Страница 926: ...854 BigIron RX Series Configuration Guide 53 1001810 01 Generalized TTL security mechanism support 26 ...
Страница 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Страница 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Страница 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Страница 998: ...926 BigIron RX Series Configuration Guide 53 1001810 01 Configuring BFD for the specified protocol 30 ...
Страница 1014: ...942 BigIron RX Series Configuration Guide 53 1001810 01 Displaying multi device port authentication information 31 ...
Страница 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Страница 1072: ...1000 BigIron RX Series Configuration Guide 53 1001810 01 IP source guard 35 Syntax show ip source guard ethernet port num ...
Страница 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Страница 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Страница 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Страница 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Страница 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Страница 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Страница 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...