5
The following table shows recommended settings:
Edit option
Field: recommended setting
General
—
Name
: the name chosen for the distributed port group
—
Port binding
:
Static Binding
—
Port allocation
:
Elastic
—
Number of ports
:
8
(increases automatically as long as
Elastic
is
selected for port allocation)
—
Network resource pool
: use default setting
—
Description
: Add details about distributed port groups
Advanced
—
Configure reset at disconnect
:
Enabled
—
Override port policies
: use default setting
Security
—
Promiscuous mode
:
Reject
—
MAC address changes
:
Reject
—
Forged transmit
:
Reject
Traffic shaping
—
Ingress traffic shaping
:
Disabled
—
Egress traffic shaping
:
Disabled
VLAN
—
VLAN type
:
VLAN
—
VLAN ID
: Refer to the
Logical Configuration Survey
Teaming and failover
—
Load balancing
:
Route
based on physical NIC load. The vMotion port
group only has one active uplink (associated with vNIC2 fabric A). The
other uplink should be in standby mode
—
Network failure detection
:
Link status only
—
Notify switches
:
Yes
—
Failback
:
Yes
Monitoring
Netflow
:
default
Traffic filtering and
marking
—
Status
: enable this option for vMotion NFS distributed port groups. All
other port groups should be disabled
—
vMotion Traffic Rule Enabled
- use the + sign to make edits
—
Action tag
—
COS value
checkbox is selected
—
Set CoS to 4
—
Set traffic direction to
Ingress
.
VMware vSphere 6.x Release Notes
information about ingress and egress parameters.
—
Type System Traffic and set Protocol/Traffic Type to vMotion
—
NFS Traffic Rule Enabled - use the + sign to make edits
—
Action tag
—
COS value
checkbox is selected
—
Set CoS to 2
—
Set traffic direction to
Ingress
.
VMware vSphere 6.x Release Notes
information about ingress and egress parameters.
—
Type IP and set Protocol/Traffic Type to Any
Managing VMware VDS
|
92
Содержание Vblock Systems 350
Страница 1: ...Dell EMC VxBlock and Vblock Systems 350 Administration Guide Document revision 1 8 October 2017 ...
Страница 114: ...Related information VMware vSphere Networking guide Managing VMware VDS 114 ...
Страница 122: ...Related information Cisco Nexus 1000V Troubleshooting Guide Managing the Cisco Nexus 1000V Series Switch 122 ...
Страница 156: ...4 On the Schedule tab schedule the task to run daily at 1 00 AM Backing up Cisco MDS switches 156 ...