Removing the uplink port profiles
Remove the uplink port profiles from the trunks that run northbound from the Cisco Nexus 1000V Switch.
Northbound traffic from the Cisco Nexus 1000V Switch is affected.
Before you begin
•
Verify that VLANs on uplinks exist in Cisco aggregation switches.
•
Verify the use of jumbo frames.
•
Obtain the IP address of the Cisco Nexus 1000V Switch VSM.
Procedure
1
Log on to the VSM.
2
Type the following commands:
configure terminal
no port-profile type ethernet PRODUCTION-UPLINK
copy run start
end
Modifying vEthernet data port profiles
Modify data port profiles for VMware VM traffic, L3 VMotion, NFS, and VSM Layer 3 Control.
Managing the Cisco Nexus 1000V Series Switch
|
118
Содержание Vblock Systems 350
Страница 1: ...Dell EMC VxBlock and Vblock Systems 350 Administration Guide Document revision 1 8 October 2017 ...
Страница 114: ...Related information VMware vSphere Networking guide Managing VMware VDS 114 ...
Страница 122: ...Related information Cisco Nexus 1000V Troubleshooting Guide Managing the Cisco Nexus 1000V Series Switch 122 ...