LS10 Installation and Operating Guide
Page 76
LS10 Installation & Operating Guide
Document # 9301H66300 Ver. 1.01
Figure 57. Automation Edit Action
•
Select
an
Action Type
from the dropdown list, using the up/down arrow keys or the mouse
scroll wheel.
Delay
is set in milliseconds (ms) with a range of 0-10000ms (10 seconds).
Input
– select the Input type from the
Change Input To
dropdown.
Mute
– Select between
On
or
Off
.
Volume
– The master volume control can be either
Set
to a specified value, or it can be
incremented or decremented (
Adjust
) through automation.
If
Run Macro
is selected, then accept or change the
Macro Name
. Touch the field to
open a keyboard screen.
Note
: This application accepts only Latin alphanumeric characters.
Trigger
– In the
Set
field, select which Trigger output (1 through 4) to use. In the
To
field,
select
Pulse
,
Low
, or
High
. If
Pulse
is selected, then enter a value in the
Width
field.
The pulse width can be set between 100ms and 1000ms in 5ms increments.
Run Command
– Touch the
Cmd
field to open a virtual keyboard screen. Enter an LS10
command to be run. Any LS10 command defined by the LS10 command API can be
executed by this action. The LS10 API command definitions are in
Appendix E, LS10
Command API
. Do not include the leading '@' character, or the trailing carriage return
when entering the command as a Run Command action (they are necessary only for
remote serial or network commands).
•
Touch
OK
when finished, or touch
Cancel
to cancel this setup.
3.21.2 Delete Event
Select an Event from the listing and touch the
Delete Event
button. A confirmation screen will appear.
Select
Delete
or Cancel.