AMT58x-PB Profibus®
29
Position and velocity values
when Class 2 (+VEL) is set (Encoder
Master)
Byte
1 … 4 5 … 8
Bit 31-24 … 7-0 31-24
…
7-0
Position
Velocity
Preset value
when any Class is set (Master
Slave)
Byte 1 2 3
4
Bit 31-24
23-16 15-8 7-0
Data 2
31
to 2
24
2
23
to 2
16
2
15
to 2
8
2
7
to 2
0
The Preset function is meant to assign a desired value to a physical
position of the encoder. The chosen physical position will get the
value set next to this item and all the previous and following positions
will get a value according to it. This function is useful, for example,
when the zero position of the encoder and the zero position of the
axis need to match. The preset value will be set for the position of the
encoder in the moment when the preset value is sent. The
Preset
value
value is sent by the Master to the Slave in
Data_Exchange
mode by setting bit 31 = “1” for 3 cycles.
The MSB of the preset value controls the preset function in the
following way:
Normal operating mode: MSB = 0 (bit 31): the encoder will make no
change in preset value.
Preset mode: MSB = 1 (bit 31): with the MSB = 1 the encoder
accepts the transferred value (bits 0 ... 30) as a preset value in binary
code.
- If
Scaling function control
= DISABLED, then
Preset value
must
be less than the
Total hardware resolution
.
- If
Scaling function control
= ENABLED, then
Preset value
must
be less than the
Total resolution
.
Содержание AMT58 Series
Страница 1: ......
Страница 8: ......
Страница 13: ...AMT58x CB CANopen 5 3 1 3 Fissaggio con flangia codice ST 58 FLNG ...
Страница 52: ......
Страница 55: ...Subject index ...
Страница 62: ...AMT58x PB Profibus 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 101: ......
Страница 102: ......
Страница 109: ......
Страница 114: ...AMT58x EC EtherCAT 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 166: ......
Страница 167: ...AMT58 PN INSTRUCTION MANUAL Absolute Encoders ...
Страница 179: ...INSTRUCTION MANUAL xiii SFC System function TCP Transmission Control Protocol TMAPC Master Application Cycle Time ...
Страница 180: ...LIST OF ABBREVIATIONS xiv AMT58 PN ...
Страница 213: ...RESETTING THE PARAMETERS TO THE DEFAULT FACTORY VALUES INSTRUCTION MANUAL 33 Figure 15 Encoder reset ...
Страница 221: ...TO TECHNOLOGY OBJECTS INSTRUCTION MANUAL 41 Figure 28 TO encoder enabled ...
Страница 231: ...INSTRUCTION MANUAL 51 ...
Страница 255: ...REAL TIME CLASS 3 IRT_TOP RT3 INSTRUCTION MANUAL 75 Figure 5 Telegram 81 IN Figure 6 Telegram 81 OUT ...
Страница 265: ...NORMAL OPERATION DIAGRAM INSTRUCTION MANUAL 85 NORMAL OPERATION DIAGRAM ...
Страница 266: ...ENCODER STATE MACHINE 86 AMT58 PN PRESET DIAGRAM ...
Страница 267: ...PARKING SENSOR DIAGRAM INSTRUCTION MANUAL 87 PARKING SENSOR DIAGRAM ...
Страница 268: ...ENCODER STATE MACHINE 88 AMT58 PN ERROR DIAGRAM Acknowledgment of acknowledgeable sensor error ...
Страница 269: ...ERROR DIAGRAM INSTRUCTION MANUAL 89 Acknowledgment of not acknowledgeable sensor error ...
Страница 284: ......
Страница 285: ......
Страница 287: ......
Страница 294: ......
Страница 299: ...AMT58x CB CANopen 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 335: ......
Страница 345: ...AMT58x DN DeviceNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 380: ...AMT58x DN DeviceNET 40 Default 21h ...
Страница 384: ...AMT58x DN DeviceNET 44 Default 00h ...
Страница 394: ......
Страница 404: ...AMT58x PB Profibus 5 3 1 3 Installation using a flange code ST 58 FLNG ...