INSTRUCTION MANUAL
13
CHAPTER 5
GETTING STARTED
QUICK START INFORMATION
The following instructions allow the operator to quickly and safely set up the device in a
standard operational mode.
For complete and detailed information please read the mentioned pages thoroughly.
• Mechanically install the device, see
Mechanical Installation, starting on page 4
;
• execute the electrical and network connections, see
Electrical Connections, starting
• switch on the +10Vdc +30Vdc power supply;
• install the GSDML file, see "
Installing the GSDML file" on page 20
• insert the Datalogic module and type of telegram in the PROFINET-IO system, see
Adding a node to the project" on page 21
• set the device name, see "
Setting the device name and the IP address" on page 26
• set the IP address and the subnet mask to the node, see "
and the IP address" on page 26
; the default address is
0.0.0.0
;
• to set the parameters, enter the
Module parameters
page, see "
; in this page it is possible, for example, to set the singleturn reso
-
lution or the total resolution, to enable the scaling function or to change the
counting direction; after entering new values, you must download the parameters
to the device; for the complete list of the default parameters see
ter List, starting on page 103
• to enable the scaling function, change the counting direction and execute the pre
-
set, the
Class 4 functionality
parameter must be enabled (=”1”), see "
NOTE
It is possible to configure the parameters also by entering the web server
via browser (see "
Integrated Web Server" on page 90
): in the Set Encoder
Registers page (see "
Setting the Parameters" on page 94
), the operator can
either enter the desired value or set it through the drop-down box in the
input field under the WRITE column; then he has to press the button
between the boxes to confirm. The value that is currently set can be found
in the box on the right under the READ column.
Содержание AMT58 Series
Страница 1: ......
Страница 8: ......
Страница 13: ...AMT58x CB CANopen 5 3 1 3 Fissaggio con flangia codice ST 58 FLNG ...
Страница 52: ......
Страница 55: ...Subject index ...
Страница 62: ...AMT58x PB Profibus 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 101: ......
Страница 102: ......
Страница 109: ......
Страница 114: ...AMT58x EC EtherCAT 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 166: ......
Страница 167: ...AMT58 PN INSTRUCTION MANUAL Absolute Encoders ...
Страница 179: ...INSTRUCTION MANUAL xiii SFC System function TCP Transmission Control Protocol TMAPC Master Application Cycle Time ...
Страница 180: ...LIST OF ABBREVIATIONS xiv AMT58 PN ...
Страница 213: ...RESETTING THE PARAMETERS TO THE DEFAULT FACTORY VALUES INSTRUCTION MANUAL 33 Figure 15 Encoder reset ...
Страница 221: ...TO TECHNOLOGY OBJECTS INSTRUCTION MANUAL 41 Figure 28 TO encoder enabled ...
Страница 231: ...INSTRUCTION MANUAL 51 ...
Страница 255: ...REAL TIME CLASS 3 IRT_TOP RT3 INSTRUCTION MANUAL 75 Figure 5 Telegram 81 IN Figure 6 Telegram 81 OUT ...
Страница 265: ...NORMAL OPERATION DIAGRAM INSTRUCTION MANUAL 85 NORMAL OPERATION DIAGRAM ...
Страница 266: ...ENCODER STATE MACHINE 86 AMT58 PN PRESET DIAGRAM ...
Страница 267: ...PARKING SENSOR DIAGRAM INSTRUCTION MANUAL 87 PARKING SENSOR DIAGRAM ...
Страница 268: ...ENCODER STATE MACHINE 88 AMT58 PN ERROR DIAGRAM Acknowledgment of acknowledgeable sensor error ...
Страница 269: ...ERROR DIAGRAM INSTRUCTION MANUAL 89 Acknowledgment of not acknowledgeable sensor error ...
Страница 284: ......
Страница 285: ......
Страница 287: ......
Страница 294: ......
Страница 299: ...AMT58x CB CANopen 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 335: ......
Страница 345: ...AMT58x DN DeviceNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Страница 380: ...AMT58x DN DeviceNET 40 Default 21h ...
Страница 384: ...AMT58x DN DeviceNET 44 Default 00h ...
Страница 394: ......
Страница 404: ...AMT58x PB Profibus 5 3 1 3 Installation using a flange code ST 58 FLNG ...