1.1.4 Available Literature for VLT HVAC Basic
Drive
-
Quick Guide MG.18.Ax.yy
-
Programming Guide MG.18.Bx.yy provides
information on how to programme and includes
complete parameter descriptions.
-
Design Guide MG.18.Cx.yy entails all technical
information about the frequency converter and
customer design and applications.
-
PC-based Configuration Tool MCT-10, MG.10.Ax.yy
enables the user to configure the frequency
converter from a Windows
™
based PC
environment.
-
Danfoss VLT
®
Energy Box software at
www.danfoss.com/BusinessAreas/DrivesSolutions
then choose PC Software Download
VLT
®
Energy Box Software allows energy
consumption comparisons of HVAC fans and
pumps driven by Danfoss drives and alternative
methods of flow control. This tool may be used to
project, as accurately as possible, the costs, savings,
and payback of using Danfoss drives on HVAC fans
and pumps.
x = Revision number
yy = Language code
Danfoss technical literature is available in print from your
local Danfoss Sales Office or online at:
www.danfoss.com/BusinessAreas/DrivesSolutions/Documen-
tations/TeDocumentation.htm
1.1.5 Definitions
Frequency converter:
I
VLT,MAX
Maximum output current.
I
VLT,N
Rated output current supplied by the frequency converter.
U
VLT, MAX
Maximum output voltage.
Input:
Control command
Start and stop the connected motor by means of LCP and
digital inputs.
Functions are divided into two groups.
Functions in group 1 have higher priority than functions in
group 2.
Group 1
Reset, Coasting stop, Reset and Coasting stop,
Quick-stop, DC braking, Stop and the [OFF] key.
Group 2
Start, Latched start, Reversing, Start reversing, Jog
and Freeze output
Motor:
Motor Running
Torque generated on output shaft and speed from zero rpm
to max. speed on motor.
f
JOG
Motor frequency when the jog function is activated (via
digital terminals).
f
M
Motor frequency.
f
MAX
Maximum motor frequency.
f
MIN
Minimum motor frequency.
f
M,N
Rated motor frequency (nameplate data).
I
M
Motor current (actual).
I
M,N
Rated motor current (nameplate data).
n
M,N
Rated motor speed (nameplate data).
n
s
Synchronous motor speed
ns =
2 ×
par. 1 − 23 × 60 s
par. 1 − 39
P
M,N
Rated motor power (nameplate data in kW or hp).
T
M,N
Rated torque (motor).
U
M
Instantaneous motor voltage.
U
M,N
Rated motor voltage (nameplate data).
Introduction
VLT HVAC Basic Drive Programming Guide
MG.18.B1.02 - VLT
®
is a registered Danfoss trademark
7
1
1