[6]
Running / no
warning
The output speed is higher than the speed
set in
. The motor is
running and there are no warnings.
[8]
Run on
reference / no
warning
The motor runs at reference speed.
[9]
Alarm
An alarm activates the output. There are
no warnings.
[10]
Alarm or
warning
An alarm or a warning activates the
output.
[11]
At torque limit The torque limit set in
parameter 4-16 Torque Limit Motor Mode
or
parameter 4-13 Motor Speed High Limit
[RPM]
has been exceeded.
[12]
Out of current
range
The motor current is outside the range set
in
[13]
Below current,
low
The motor current is lower than set in
parameter 4-50 Warning Current Low
[14]
Above current,
high
The motor current is higher than set in
4-51 Warning Current High
.
[16]
Below speed,
low
The output speed is lower than the setting
in
parameter 4-52 Warning Speed Low
.
[17]
Above speed,
high
The output speed is higher than the
setting in
[18]
Out of
feedback
range
The feedback is outside the range set in
parameter 4-56 Warning Feedback Low
and
parameter 4-57 Warning Feedback High
[19]
Below
feedback low
The feedback is below the limit set in
parameter 4-56 Warning Feedback Low
.
[20]
Above
feedback high
The feedback is above the limit set in
parameter 4-57 Warning Feedback High
[21]
Thermal
warning
The thermal warning turns on when the
temperature exceeds the limit in the
motor, the frequency converter, the brake
resistor, or the thermistor.
[25]
Reverse
The motor runs (or is ready to run)
clockwise when there is a logic 0 signal
and counterclockwise when there is a logic
1 signal. The output changes as soon as
the reversing signal is applied.
[26]
Bus OK
Active communication (no time-out) via
the serial communication port.
[27]
Torque limit
and stop
Use this option to perform a coasting stop
and in torque limit condition. If the
frequency converter has received a stop
signal and is at the torque limit, the signal
is logic 0.
[28]
Brake, no
warning
The brake is active and there are no
warnings.
[29]
Brake ready,
no fault
The brake is ready for operation and there
are no faults.
[30]
Brake fault
(IGBT)
The output is logic 1 when the brake IGBT
is short-circuited. Use this function to
protect the frequency converter if there is
a fault on the brake modules. Use the
output/relay to cut out the main voltage
from the frequency converter.
[35]
External
Interlock
The external interlock function has been
activated via one of the digital inputs.
[40]
Out of ref
range
[41]
Below
reference low
[42]
Above
reference high
[45]
Bus Ctrl
[46]
Bus Ctrl 1 if
timeout
[47]
Bus Ctrl 0 if
timeout
[60]
Comparator 0
See parameter group 13-1* Comparators. If
comparator 0 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[61]
Comparator 1
See parameter group 13-1* Comparators. If
comparator 2 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[62]
Comparator 2
See parameter group 13-1* Comparators. If
comparator 2 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[63]
Comparator 3
See parameter group 13-1* Comparators. If
comparator 3 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[64]
Comparator 4
See parameter group 13-1* Comparators. If
comparator 4 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[65]
Comparator 5
See parameter group 13-1* Comparators. If
comparator 5 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[70]
Logic Rule 0
See parameter group 13-4* Logic Rules. If
logic rule 0 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[71]
Logic Rule 1
See parameter group 13-4* Logic Rules. If
logic rule 1 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[72]
Logic Rule 2
See parameter group 13-4* Logic Rules. if
logic rule 2 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[73]
Logic Rule 3
See parameter group 13-4* Logic Rules. If
logic rule 3 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[74]
Logic Rule 4
See parameter group 13-4* Logic Rules. If
logic rule 4 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[75]
Logic Rule 5
See parameter group 13-4* Logic Rules. if
logic rule 5 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[80]
SL Digital
Output A
See
parameter 13-52 SL Controller Action
The input will go high whenever the smart
logic action
[38] Set dig. out. A high
is
Parameter Descriptions
VLT
®
HVAC Drive FC 102
74
Danfoss A/S © 03/2015 All rights reserved.
MG11CE02
3