16-77 Analog Out X30/8 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-82 Fieldbus REF 1
0 N/A
All set-ups
FALSE
0
N2
16-84 Comm. Option STW
0 N/A
All set-ups
FALSE
0
V2
16-85 FC Port CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-86 FC Port REF 1
0 N/A
All set-ups
FALSE
0
N2
16-9* Diagnosis Readouts
16-90 Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
16-91 Alarm Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-92 Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
16-93 Warning Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-94 Ext. Status Word
0 N/A
All set-ups
FALSE
0
Uint32
16-95 Ext. Status Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-96 Maintenance Word
0 N/A
All set-ups
FALSE
0
Uint32
5.1.17 18-** Info & Rèadouts
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
18-0* Maintenance Log
18-00 Maintenance Log: Item
0 N/A
All set-ups
FALSE
0
Uint8
18-01 Maintenance Log: Action
0 N/A
All set-ups
FALSE
0
Uint8
18-02 Maintenance Log: Time
0 s
All set-ups
FALSE
0
Uint32
18-03 Maintenance Log: Date and Time
ExpressionLimit
All set-ups
FALSE
0
TimeOfDay
18-1* Fire Mode Log
18-10 FireMode Log:Event
0 N/A
All set-ups
FALSE
0
Uint8
18-11 Fire Mode Log: Time
0 s
All set-ups
FALSE
0
Uint32
18-12 Fire Mode Log: Date and Time
ExpressionLimit
All set-ups
FALSE
0
TimeOfDay
18-3* Inputs & Outputs
18-30 Analog Input X42/1
0 N/A
All set-ups
FALSE
-3
Int32
18-31 Analog Input X42/3
0 N/A
All set-ups
FALSE
-3
Int32
18-32 Analog Input X42/5
0 N/A
All set-ups
FALSE
-3
Int32
18-33 Analog Out X42/7 [V]
0 N/A
All set-ups
FALSE
-3
Int16
18-34 Analog Out X42/9 [V]
0 N/A
All set-ups
FALSE
-3
Int16
18-35 Analog Out X42/11 [V]
0 N/A
All set-ups
FALSE
-3
Int16
18-36 Analog Input X48/2 [mA]
0 N/A
All set-ups
TRUE
-3
Int32
18-37 Temp. Input X48/4
0 N/A
All set-ups
TRUE
0
Int16
18-38 Temp. Input X48/7
0 N/A
All set-ups
TRUE
0
Int16
18-39 Temp. Input X48/10
0 N/A
All set-ups
TRUE
0
Int16
18-5* Ref. & Feedb.
18-50 Sensorless Readout [unit]
0 SensorlessUnit
All set-ups
FALSE
-3
Int32
5.1.18 20-** FC Closed Loop
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
20-0* Feedback
20-00 Feedback 1 Source
[2] Analog Input 54
All set-ups
TRUE
-
Uint8
20-01 Feedback 1 Conversion
[0] Linear
All set-ups
FALSE
-
Uint8
20-02 Feedback 1 Source Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
20-03 Feedback 2 Source
[0] No function
All set-ups
TRUE
-
Uint8
20-04 Feedback 2 Conversion
[0] Linear
All set-ups
FALSE
-
Uint8
Parameter Lists
Programming Guide
MG11CE02
Danfoss A/S © 03/2015 All rights reserved.
237
5
5