Block
D
iag
ram
Name
Spar
e
Par
t
Number
Spar
e
par
t
name
Commen
ts
525–690
V
A
C
(T7)
E1h/E3h
E2h/E4h
FC
102
N450
N500
N560
N630
N710
N800
FC
103
N450
N500
N560
N630
N710
N800
FC
202
N450
N500
N560
N630
N710
N800
FC
302
N355
N400
N500
N560
N630
N710
176F6664
Busbar
, DC
neg
, DC
link
ind
to
C
APB
, E1,E3
Connec
ts
DC
c
oil
-
input
to
cap
bank
, r
igh
t
side
of
dr
iv
e
1
1
1
1
–
–
176F6665
Busbar
, DC
neg
, DC
link
ind
to
C
APB
, E2,E4
Connec
ts
DC
c
oil
-
input
to
cap
bank
, r
igh
t
side
of
dr
iv
e
–
–
–
–
1
1
176F6666
Busbar
, DC
pos
, DC
link
ind
to
C
APB
, E1,E2
Connec
ts
DC
c
oil
+
input
to
cap
bank
, lef
t
side
of
dr
iv
e
1
1
1
1
–
–
176F6667
Busbar
, DC
pos
, DC
link
ind
to
C
APB
, E2,E4
Connec
ts
DC
c
oil
+
input
to
cap
bank
, lef
t
side
of
dr
iv
e
–
–
–
–
1
1
176F6684
Busbar
insulat
or
set
, T7
E1
P4001
Set
of
3
cap
bank
busbars
with
M
ylar
insulat
ors
1
1
1
1
–
–
176F6685
Busbar
insulat
or
set
, T7
E2
P4001
Set
of
3
cap
bank
busbars
with
M
ylar
insulat
ors
–
–
–
–
1
1
176F6673
Busbar
, IGB
T
AC
OUTPUT
, E1,E3
IGB
T
AC
output
, goes
o
ver
the
IGB
T,
1
per
k
it
3
3
3
3
–
–
176F6674
Busbar
, IGB
T
AC
OUTPUT
, E2,E4
IGB
T
AC
output
, goes
o
ver
the
IGB
T,
1
per
k
it
–
–
–
–
3
3
176F6659
Busbar
, cur
ren
t
sensor
, E1hE3h
Busbars
thr
ough
sensors
, 1
per
k
it
1
1
1
1
–
–
176F6660
Busbar
, cur
ren
t
sensor
, E2hE4h
Busbars
thr
ough
sensors
, 1
per
k
it
–
–
–
–
1
1
176F3839
Busbar
, mot
or
, U
, E1hE3h
Busbar
, c
onnec
ts
C/T
bar
to
r
igh
t
angle
bar
1
1
1
1
–
–
176F3840
Busbar
, mot
or
, V
, E1hE3h
Busbar
, c
onnec
ts
C/T
bar
to
r
igh
t
angle
bar
1
1
1
1
–
–
176F3841
Busbar
, mot
or
, W
, E1hE3h
Busbar
, c
onnec
ts
C/T
bar
to
r
igh
t
angle
bar
1
1
1
1
–
–
176F3844
Busbar
, mot
or
, U
, E2hE4h
Busbar
, c
onnec
ts
C/T
bar
to
r
igh
t
angle
bar
–
–
–
–
1
1
176F3846
Busbar
, mot
or
, V
, E2hE4h
Busbar
, c
onnec
ts
C/T
bar
to
r
igh
t
angle
bar
176F3845
Busbar
, mot
or
, W
, E2hE4h
Busbar
, c
onnec
ts
C/T
bar
to
r
igh
t
angle
bar
TB1
176F6689
Busbar
ter
minal
, E1h–E4h
M
ains
ter
minal
busbars
(L1,L2,L3)
3
3
3
3
3
3
TB2
176F6689
Busbar
ter
minal
, E1h–E4h
M
ot
or
ter
minal
busbars
(U
,V
,W
)
3
3
3
3
3
3
O
ther
P
ar
ts
176F3353
D
oor
fan
filter
Dh
fr
ame
pack
age
of
10
IP21/IP54
door
filter
2
per
dr
iv
e,
10
per
k
it
2
2
2
2
2
2
176F3375
D
oor
v
en
t
kit
IP21/IP54
Dh
fr
ame
D
oor
v
en
t
kit
, no
fan
2
2
2
2
2
2
TB1
176F6686
Ter
minal
suppt
, main,
mot
or
, E1h–E4h
M
ains
ter
minal
insulation
block
3
3
3
3
3
3
TB2
176F6686
Ter
minal
suppt
, main,
mot
or
, E1h–E4h
M
ot
or
ter
minal
insulation
block
3
3
3
3
3
3
176F6668
Co
ver
, E3h
fr
on
t,
top
panel
Fr
on
t
co
ver
IP20
E3h
IP20
IP20
IP20
IP20
–
–
176F6669
Co
ver
, E3h
fr
on
t,
lo
w
er
panel
Fr
on
t
co
ver
IP20
E3h
IP20
IP20
IP20
IP20
–
–
176F6670
Co
ver
, E4h
fr
on
t,
top
panel
Fr
on
t
co
ver
IP20
E4h
–
–
–
–
IP20
IP20
176F6671
Co
ver
, E4h
fr
on
t,
lo
w
er
panel
Fr
on
t
co
ver
IP20
E4h
–
–
–
–
IP20
IP20
176F6678
Co
ver
, mains
shield
c
ov
ers
, E1
M
ains
shield
E1
1
1
1
1
–
–
176F6679
Co
ver
, mains
shield
c
ov
ers
, E2
M
ains
shield
E2
–
–
–
–
1
1
Spare Parts
VLT
®
FC Series, D1h–D8h, Da2/Db2/Da4/Db4, E1h–E4h, J8/J9
354
Danfoss A/S © 02/2019 All rights reserved.
MG94A502
15
15
Содержание VLT FC Series
Страница 2: ......
Страница 369: ...Index Service Guide MG94A502 Danfoss A S 02 2019 All rights reserved 367...