11.2.7 EMC Shield
To remove or reinstall the EMC shield, use the following
steps. See
.
Disassembly
1.
Remove 1 screw (T20) from the EMC shield.
2.
Remove the EMC shield from the drive.
Reassembly
Tighten fasteners according to
1.
Position the EMC shield in the drive.
2.
Secure 1 screw (T20) in the EMC shield.
11.2.8 Brake Terminal Block (Optional)
Drives can include an optional brake. To remove or reinstall
the optional brake terminal block, use the following steps.
Refer to
.
Disassembly
1.
Disconnect the brake wiring.
2.
To remove the R(+) terminal:
2a
Remove 1 thread-forming screw (T25)
from the terminal block.
2b
Remove 1 screw (T40).
3.
To remove the R(-) terminal:
3a
Remove 1 thread-forming screw (T25)
from the terminal block.
3b
Remove 1 nut (13 mm).
4.
Remove the brake terminal block by removing 2
nuts (13 mm).
Reassembly
Tighten fasteners according to
.
1.
Position the brake terminal block in the drive and
secure 2 nuts (13 mm).
2.
To attach the R(-) terminal:
2a
Fasten 1 thread-forming screw (T25) in
the terminal block.
2b
Fasten 1 nut (13 mm).
3.
To attach the R(+) terminal:
3a
Fasten 1 thread-forming screw (T25) in
the terminal block.
3b
Secure 1 screw (T40).
4.
Reconnect the brake wiring.
D2h/D4h/D7h/D8h/J9 Unit Dis...
VLT
®
FC Series, D1h–D8h, Da2/Db2/Da4/Db4, E1h–E4h, J8/J9
196
Danfoss A/S © 02/2019 All rights reserved.
MG94A502
11
11
Содержание VLT FC Series
Страница 2: ......
Страница 369: ...Index Service Guide MG94A502 Danfoss A S 02 2019 All rights reserved 367...