Disassembly in E2h/E4h drives
In E2h/E4h drives, the DC snubber capacitors are located
under the Y-shaped busbars. Refer to
.
1.
Remove the input plate. Refer to
chapter 13.2.9 Input Plate with Busbars
and
chapter 13.2.10 Split Input Plate with Options
2.
Remove 3 nuts (13 mm), 1 at the top of each
current sensor busbar.
3.
Remove 6 nuts (13 mm), 2 at the top of each
IGBT output busbar. Remove the IGBT output
busbars from the drive.
4.
Remove 12 nuts (40 mm), 4 each DC snubber
capacitor pair.
5.
Remove the 3 DC snubber capacitor pairs from
the drive.
Reassembly in E2h/E4h drives
Tighten fasteners according to
.
1.
Place the DC snubber capacitor pairs in the drive.
2.
Secure 12 nuts (40 mm), 4 in each DC snubber
capacitor pair.
3.
Position the IGBT output busbars in the drive.
Secure 6 nuts (13 mm), 2 at the top of each IGBT
output busbar.
4.
Secure 3 nuts (13 mm), 1 at the top of each
current sensor busbar.
5.
Replace the input plate. Refer to
chapter 13.2.9 Input Plate with Busbars
and
chapter 13.2.10 Split Input Plate with Options
.
1
2
3
4
130BF877.10
1
Y-shaped busbar
3
DC snubber capacitor pair
2
Nut (40 mm)
4
DC bus plates
Illustration 13.19 DC Snubber Capacitors in E2h/E4h Drives