11.2.15 Inrush Card
To remove or replace the inrush card, use the following steps. Refer to
.
Disassembly
1.
Remove the power card mounting plate. Refer to
chapter 11.2.3 Power Card Mounting Plate
2.
Unplug the cable from the inrush card connector
MK1802.
3.
Remove 2 thread-forming screws (T20).
4.
Remove 5 screws (T20) from the inrush card.
5.
Remove the inrush card from the unit.
Reassembly
Tighten hardware according to
.
1.
Position the inrush card in the drive.
2.
Secure 5 screws (T20) in the inrush card.
3.
Secure 2 thread-forming screws (T20).
4.
Connect the cable to the inrush card connector
MK1802.
5.
Replace the power card mounting plate. Refer to
chapter 11.2.3 Power Card Mounting Plate
D2h/D4h/D7h/D8h/J9 Unit Dis...
Service Guide
MG94A502
Danfoss A/S © 02/2019 All rights reserved.
207
11
11