2.1.2 General Technical Data
Mains supply, TT, TN and IT* (L1, L2, L3)
Supply voltage 380-480 V units
3x380/400/415/440/460/480 V ±10%
Supply frequency
50/60 Hz
Max. imbalance of supply voltage
±2% of rated supply voltage
Power factor / cos
max. 0.9/1.0 at rated load
No. of switching operations on supply input L1, L2, L3
approx. 1 time/2 min
*) Not valid for RFI class 1B units
Torque characteristics
Starting torque/overload torque
160% for 1 min
Continuous torque
see above
Control card, digital/pulse inputs
Number of programmable digital inputs
4
Terminal nos.
X101-2, -3, -4, -5
Voltage level
0-24 V DC (PNP positive logics)
Voltage level, logic 0
<5 V DC
Voltage level, logic 1
>10 V DC
Maximum voltage on input
28 V DC
Input resistance, R
i
approx. 2 kΩ
Scanning time
20 mses
Control card, pulse input
No. of programmable pulse inputs
1
Terminal nos.
X101-3
Max. frequency on terminal 3, open collector/push pull 24 V
8 kHz/70 kHz
Resolution
10 bit
Accuracy (0.1-1 kHz), terminal 3
Max. error: 0.5% of full scale
Accuracy (1-12 kHz), terminal 3
Max. error: 0.1% of full scale
Control card, analogue inputs
No. of programmable analogue voltage inputs
1
Terminal nos.
X101-2
Voltage level
0-10 V DC (scalable)
Input resistance, R
i
approx. 10 kΩ
No. of programmable analogue current inputs
1
Terminal no.
X101-1
Current range
0 - 20 mA (scalable)
Input resistance, R
i
approx. 300 Ω
Resolution
9 bit
Accuracy on input
Max. error 1% of full scale
Scanning time
20 ms.
Control card, digital/pulse and analogue outputs
No. of programmable digital and analogue outputs
1
Terminal nos.
X101-9
Voltage level at digital output/load
0 - 24 V DC/25 mA
Current at analogue output
0 - 20 mA
Maximum load to frame (terminal 8) at analogue output
R
LOAD
500 Ω
Accuracy of analogue output
Max. error: 1.5% of full scale
Resolution on analogue output.
8 bit
Relay output
No. of programmable relay outputs
1
Terminal number (resistive and inductive load)
1-3 (break), 1-2 (make)
Max. terminal load (AC1) on 1-3, 1-2
250 V AC, 2A, 500 VA
Installation
VLT
®
DriveMotor FCM Series
12
MG03BA02 - VLT
®
is a registered Danfoss trademark
2
2
Содержание VLT Brook Crompton Motor FCM 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT Brook Crompton Motor FCM 300 www danfoss com drives...
Страница 2: ......
Страница 26: ...Illustration 2 5 Installation VLT DriveMotor FCM Series 24 MG03BA02 VLT is a registered Danfoss trademark 2 2...
Страница 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Страница 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Страница 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...