Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown is a calculated value of the given motor
current.
This value is updated every 320 ms.
521
Data read-out: Torque
Value:
XXX.X%
[XXXX]
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown is the torque, with sign, supplied to the
motor shaft. The value is given as a percentage of the
rated torque.
There is not exact linearity between 160% motor current
and torque in relation to the rated torque. Due to
tolerances and temperature differences some motors
supply more torque than that. Consequently, the min.
value and the max. value will depend on the max./min.
motor current.
This value is updated every 320 ms.
522
Data read-out: Power, kW
Value:
XX.XX kW
[XXXX]
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown is calculated on the basis of the actual
motor voltage and motor current.
This value is updated every 320 ms.
523
Data read-out: Power, HP
Value:
XX.XX HP (US)
[XXXX]
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown is calculated on the basis of the actual
motor voltage and motor current. The value is indicated in
the form of HP.
This value is updated every 320 ms.
524
Data read-out: Motor voltage
Value:
XXX.X V
[XXXX]
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown is a calculated value used for controlling
the motor.
This value is updated every 320 ms.
525
Data read-out: DC link voltage
Value:
XXXX V
[XXXX]
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown is a measured value.
The value is filtered, which means that approx. 1.3 seconds
may pass from an input value changes until the data read-
out changes values.
This value is updated every 320 ms.
527
Data read-out: FC therm.
Value:
0-100%
[0-100]
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
Only whole numbers are displayed.
This value is updated every 160 ms.
528
Data read-out: Digital input
Value:
Unit
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown indicates the signal status from the 4
digital terminals (2, 3, 4, and 5).
This value is updated every 20 ms.
533
Data read-out: External reference %
Value:
-200.0 to +200.0%
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value stated gives, as a percentage, the sum of
external references (sum of analogue/bus/pulse).
This value is updated every 80 ms.
534
Data read-out: Status word, binary
Value:
Unit
Programming
VLT
®
DriveMotor FCM Series
72
MG03BA02 - VLT
®
is a registered Danfoss trademark
3
3
Содержание VLT Brook Crompton Motor FCM 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT Brook Crompton Motor FCM 300 www danfoss com drives...
Страница 2: ......
Страница 26: ...Illustration 2 5 Installation VLT DriveMotor FCM Series 24 MG03BA02 VLT is a registered Danfoss trademark 2 2...
Страница 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Страница 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Страница 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...